Improved calculation method of reinforced concrete elements strength on inclined sections
Autor: | Leonid Karabash, Оksana Dovzhenko, Оlena Maliovana, Volodymyr Pohribnyi |
---|---|
Rok vydání: | 2019 |
Předmět: |
disk model
Materials science business.industry lcsh:Mechanical engineering and machinery minimum value of limit force lcsh:TA1001-1280 General Medicine Structural engineering truss analogy Reinforced concrete coefficient of transverse reinforcement lcsh:TJ1-1570 Astrophysics::Earth and Planetary Astrophysics lcsh:Transportation engineering business boundary of failure cases realization |
Zdroj: | Збірник наукових праць: Серія: Галузеве машинобудування, будівництво, Vol 1, Iss 52, Pp 75-81 (2019) |
ISSN: | 2518-1106 2409-9074 |
DOI: | 10.26906/znp.2019.52.1679 |
Popis: | Application boundaries of the truss analogy and disk model methods to the strength calculation of reinforced concrete flexuralelements inclined sections are established. Areas of structures failure by virtual compressed element (inclined strip) andcompressed zone over dangerous inclined crack under the shear force are determined. The criterion of minimum limit force,which is perceived by the elements, is applied. Influence of concrete class, relative shear span and transverse reinforcementintensity on elements strength based on variational method in plasticity theory is specified. The data concerning the values ofthe transverse reinforcement coefficient at the boundaries of the failure from shear within the inclined strip and compressedzone over the dangerous crack are obtained. |
Databáze: | OpenAIRE |