Canine fetal echocardiography: correlations for the analysis of cardiac dimensions
Autor: | Daniela Aparecida Ayres Garcia, Marlos Gonçalves Sousa, Amália Turner Giannico, Tilde Rodrigues Froes, Elaine Mayumi Ueno Gil |
---|---|
Rok vydání: | 2015 |
Předmět: |
medicine.medical_specialty
Correlation coefficient Fetal heart Breeding 030204 cardiovascular system & hematology Body size 03 medical and health sciences Dogs Fetal Heart 0302 clinical medicine Pregnancy medicine.artery Internal medicine medicine Animals Body Size Fetus 030219 obstetrics & reproductive medicine General Veterinary medicine.diagnostic_test business.industry Regression analysis General Medicine Echocardiography Cardiac chamber Pulmonary artery cardiovascular system Cardiology Regression Analysis Female business Fetal echocardiography |
Zdroj: | Veterinary Research Communications. 40:11-19 |
ISSN: | 1573-7446 0165-7380 |
DOI: | 10.1007/s11259-015-9648-z |
Popis: | The aim of this study was to develop regression models for correlation of canine fetal heart development with body size to characterize normal development or suggest cardiac anomalies. Twenty clinically healthy pregnant bitches, either brachycephalic and non-brachycephalic, were examined ultrasonographically. Transabdominal fetal echocardiography was conducted every 4 days from the beginning of cardiac chambers differentiation until parturition. Ten cardiac parameters were measured: length, width and diameter of the heart; heart area; left and right ventricular dimensions; left and right atrial dimensions; and aortic and pulmonary artery diameter. Femoral length, biparietal diameter and abdominal cross-sectional area were also recorded. Regression equations were developed for each parameter of fetal body size, and linear and logarithmic models were compared. The model with the highest correlation coefficient was chosen to produce equations to calculate relative dimensions based on the correlations. Only the left-ventricular chamber differed between the two racial groups. Biparietal diameter was the independent parameter that produced the highest correlation coefficient for the most fetal cardiac dimensions, although good correlations were also observed using femoral length and abdominal cross-sectional area. Heart width and heart diameter were used as surrogates of cardiac development, as these measurements showed the best statistical correlation. Quantitative evaluation of fetal cardiac structures can be used to monitor normal and abnormal cardiac development. |
Databáze: | OpenAIRE |
Externí odkaz: |