Effect of priming agents on shear bond strengths of resin-based luting agents to a translucent zirconia material
Autor: | Kei Kubochi, Hideo Matsumura, Futoshi Komine, Ryosuke Fushiki, Shogo Yagawa, Fumiaki Kimura |
---|---|
Rok vydání: | 2017 |
Předmět: |
Boron Compounds
Dental Stress Analysis Materials science Chemical Phenomena Dental Cements 02 engineering and technology 03 medical and health sciences Dental Materials 0302 clinical medicine Methylmethacrylates Dentistry (miscellaneous) Cubic zirconia Composite material Clearfil Ceramic Primer Dental Restoration Permanent Bond strength Dental Bonding Thiones Luting agent 030206 dentistry 021001 nanoscience & nanotechnology Artificial aging Alloy Primer Shear bond Resin Cements Resins Synthetic Methacrylates Zirconium Oral Surgery 0210 nano-technology Shear Strength |
Zdroj: | Journal of prosthodontic research. 62(2) |
ISSN: | 2212-4632 |
Popis: | Purpose The purpose of the present study was to evaluate the effect of priming agents and artificial aging with thermocycling on shear bond strengths of two resin-based luting agents to a translucent zirconia material. Methods A total of 308 pairs of translucent zirconia disk specimens were divided into seven treatment groups: Alloy Primer (ALP), Clearfil Ceramic Primer Plus (CCP), Meta Fast Bonding Liner (MFB), MR. bond (MRB), Super-Bond PZ Primer Liquid B (PZB), V-Primer (VPR), and an unprimed group (UP). The specimens in each group were bonded with Panavia V5 Universal (UNI) and Opaque shade (OPA). Shear bond strengths (n = 11 each) were tested before and after 5000 thermocycles. The data were analyzed with the Kruskal–Wallis test and the Steel–Dwass test. Results For both 0 and 5000 thermocycles, the ALP (47.8 and 41.5 MPa, respectively) and CCP (45.8 and 42.3 MPa, respectively) groups showed significantly higher bond strengths than other groups in the UNI luting agent. For the OPA luting agent, CCP group (45.8 MPa) exhibited the highest pre-thermocycling bond strength in all groups. The ALP (32.4 MPa) and CCP (36.5 MPa) groups had significantly higher post-thermocycling shear bond strengths than other groups. In several groups, the shear bond strengths of the UNI luting agent were significantly higher than those of the OPA luting agent before and after thermocycling. Conclusions Application of priming agents containing hydrophobic phosphate monomer (MDP) yielded the durable bond strengths of resin-based luting agents to a translucent zirconia material. |
Databáze: | OpenAIRE |
Externí odkaz: |