Influence of the Intracanal Material and Metal Artifact Reduction Tool in the Detection of the Second Mesiobuccal Canal in Cone-beam Computed Tomographic Examinations
Autor: | Matheus Lima Oliveira, Lucas de Paula Lopes Rosado, Fernanda Bulhões Fagundes, Deborah Queiroz Freitas, Frederico Sampaio Neves |
---|---|
Rok vydání: | 2020 |
Předmět: |
0301 basic medicine
Molar Orthodontics Dental Pulp Cavity Reproducibility Cone beam computed tomography medicine.medical_specialty Tomographic reconstruction Materials science Root Canal Obturation Receiver operating characteristic Reproducibility of Results 030206 dentistry Cone-Beam Computed Tomography Endodontics 03 medical and health sciences 030104 developmental biology 0302 clinical medicine medicine Humans Tooth Root Artifacts General Dentistry Finland |
Zdroj: | Journal of Endodontics. 46:1067-1073 |
ISSN: | 0099-2399 |
DOI: | 10.1016/j.joen.2020.04.011 |
Popis: | Introduction The aim of this study was to evaluate the influence of different intracanal materials and the metallic artifact reduction (MAR) tool of cone-beam computed tomographic (CBCT) imaging on the detection of the second mesiobuccal (MB2) canal in maxillary first molars. Methods Forty maxillary first molars were selected; half of them had the MB2 canal in the mesiobuccal root confirmed by micro–computed tomographic imaging. All teeth were instrumented, except for the MB2 canal, and filled with gutta-percha, which was passively inserted up to the working length. Each tooth was individually inserted into a dry human skull, and CBCT scans were performed using the OP300 device (Instrumentarium Dental, Tuusula, Finland) with and without the use of the MAR tool. For each scanned tooth, the following intracanal materials were used in the palatal root: gutta-percha, silver palladium, nickel chromium, and cobalt chromium. Five examiners assessed the images for the detection of the MB2 canal using a 5-point scale. The weighted kappa test was applied to evaluate intra- and interexaminer reproducibility. The diagnostic values (sensitivity, specificity, and area under the receiver operating characteristic curve) were calculated in the different groups and compared using 2-way analysis of variance and the Tukey post hoc test. Results The intra- and interobserver agreement ranges for the different conditions were studied. The diagnostic values were not significantly different (P > .05) regardless of the intracanal material and the use of the MAR tool. Conclusions The presence of different intracanal materials and MAR activation does not influence CBCT-based detection of MB2 canals. |
Databáze: | OpenAIRE |
Externí odkaz: |