Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system
Autor: | Roberto Ferrari, E. Baldo, Toselli Tiziano, Claudio Pratola, Pasquale Notarstefano |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2006 |
Předmět: |
Aortic valve
Male medicine.medical_specialty Radiofrequency ablation medicine.medical_treatment Ventricular tachycardia Coronary Angiography Non-contact mapping Transseptal catheterization Ventricular tachycardia ablation law.invention law Physiology (medical) medicine.artery Internal medicine medicine Humans Aged Aorta business.industry Body Surface Potential Mapping Balloon catheter Signal Processing Computer-Assisted Middle Aged Ablation medicine.disease Catheter medicine.anatomical_structure Ventricle cardiovascular system Cardiology Catheter Ablation Tachycardia Ventricular Feasibility Studies Female Radiology Cardiology and Cardiovascular Medicine business Cardiomyopathies Electrophysiologic Techniques Cardiac |
Popis: | Radiofrequency ablation of fast and unstable left ventricular tachycardia (VT) usually requires non-contact mapping. The procedure is usually performed by a retrograde-transaortic route, requiring a double femoral artery puncture, for the 9F multielectrode catheter and the 7F ablation catheter which are advanced through the aorta and aortic valve into the left ventricle (LV). Reported limitations of the procedure are due to the stiffness of the balloon catheter, particularly in patients with tortuous peripheral arteries, atherosclerotic aorta, or with aortic stenosis. The aim of our study was to test the feasibility and assess the safety of a transseptal approach for left VT non-contact mapping and ablation.Ten patients with multiple cardiac defibrillator shocks because of fast and unstable VT were selected for non-contact mapping and ablation. After a double transseptal puncture the multielectrode catheter (Ensite Array, St. Jude Medical) was advanced through a standard 10F introducer to a stable position in the LV apex over a 260 cm length 0.035 J-tip guidewire. The ablation catheter (Celsius Thermo-cool, Biosense Webster) was then inserted through the second 8F introducer. Twenty-five monomorphic sustained ventricular tachycardia were induced and ablated at the level of the diastolic pathway or exit point revealed by unipolar isopotential mapping. The total procedural and fluoroscopy times were 209 +/- 32 min and 28.5 +/- 9.27 min, respectively, which were comparable to those described with the traditional retrograde-transaortic approach. No major complication related with the transseptal approach were reported.A transseptal approach can be a feasible and effective alternative approach for mapping and ablation of fast and unstable left VT with a non-contact mapping system. |
Databáze: | OpenAIRE |
Externí odkaz: |