A simpleex vivomodel for teaching Descemet membrane endothelial keratoplasty

Autor: Walter Sekundo, Michael Petrak, Gerrit R. J. Melles, Chryssanthi Koutsandrea, Konstantinos Droutsas, Ilias Georgalas
Rok vydání: 2014
Předmět:
Zdroj: Acta Ophthalmologica. 92:e362-e365
ISSN: 1755-375X
DOI: 10.1111/aos.12371
Popis: Purpose To describe a simple ex vivo porcine model for teaching Descemet Membrane Endothelial Keratoplasty (DMEK). Methods Twenty freshly enucleated porcine eyes were used to create a pseudo-graft from the porcine lens capsule and implant it into an intact porcine globe using the standardized ‘no-touch’ technique of the Netherlands Institute for Innovative Ocular Surgery (NIIOS). Results The DMEK pseudo-graft could be inserted, centred, unfolded and appositioned in all cases. Conclusions Practicing DMEK surgery under wetlab conditions was feasible by the described simple and low-cost model. This new tool may facilitate the adaptation of DMEK by cornea surgeons.
Databáze: OpenAIRE