Performance comparison of a flow cytometry immunoassay for intracellular cytokine staining and the QuantiFERON® SARS-CoV-2 test for detection and quantification of SARS-CoV-2-Spike-reactive-IFN-γ-producing T cells after COVID-19 vaccination

Autor: Nuria Tormo, Estela Giménez, María Martínez-Navarro, Eliseo Albert, David Navalpotro, Ignacio Torres, Concepción Gimeno, David Navarro
Rok vydání: 2022
Předmět:
Zdroj: European Journal of Clinical Microbiology & Infectious Diseases. 41:657-662
ISSN: 1435-4373
0934-9723
DOI: 10.1007/s10096-022-04422-7
Popis: We compared the performance of an in-house-developed flow cytometry assay for intracellular cytokine staining (FC-ICS) and a commercially-available cytokine release assay (the QuantiFERON® SARS-CoV-2 Test [QF]) for detection and quantification of SARS-CoV-2-Spike (S)-reactive-IFN-γ-producing T cells after COVID-19 vaccination.The sample included 141 individuals (all male; median age, 42 years; 20-72) who had been fully vaccinated with the Comirnaty® COVID-19 vaccine (at a median of 114 days; 34-145). Prior to vaccination, 91 were categorized as being SARS-CoV-2-naïve and 50 as SARS-CoV-2-experienced. A whole blood-based FC-ICS using 15-mer overlapping peptides encompassing the entire SARS-CoV-2 S protein was used for enumeration of virus-specific IFN-γ-producing CD4The FC-ICS and the QF assays returned significantly discordant qualitative results in both the entire cohort (P0.001 with QF Ag1 and QF Ag2) and in SARS-CoV-2-naïve participants alone (P=0.005 and P=0.01, respectively). Discrepant results mostly involved FC-ICS positive/QF negative specimens. Overall, no correlation was found either between SARS-CoV-2 IFN-γ- CD4The data suggest a greater sensitivity for the FC-ICS assay than the QF test, and urge caution when comparing SARS-CoV-2 T-cell immune responses assessed using different analytical platforms.
Databáze: OpenAIRE