Safety and Efficacy of C2 Pedicle Screws Placed With Anatomic and Lateral C-Arm Guidance
Autor: | Tyler R. Koski, Aruna Ganju, Shaden Marzouk, Thomas Morrison, Stephen L. Ondra |
---|---|
Rok vydání: | 2006 |
Předmět: |
Adult
Male medicine.medical_specialty Adolescent Radiography Bone Screws Biplane Prosthesis Implantation Imaging Three-Dimensional medicine Humans Fluoroscopy Orthopedics and Sports Medicine Pedicle screw Image guidance Aged Retrospective Studies Fixation (histology) Aged 80 and over Orthodontics medicine.diagnostic_test business.industry Middle Aged Sagittal plane Surgery Spinal Fusion medicine.anatomical_structure Coronal plane Cervical Vertebrae Female Neurology (clinical) Tomography X-Ray Computed business Follow-Up Studies |
Zdroj: | Spine. 31:E263-E267 |
ISSN: | 0362-2436 |
DOI: | 10.1097/01.brs.0000214882.34674.be |
Popis: | STUDY DESIGN This is a retrospective review of 150 C2 pedicle screw placements. Candidates had their C2 pedicle morphology assessed through three-dimensional imaging, including preoperative image guidance. After surgery, the patients were serially CT scanned. Follow-up, with fusion assessment, ranged from 1 to 12 years. OBJECTIVE We will show that an open technique combined with lateral C-arm guidance provides rapid placement of C2 pedicle screws. SUMMARY OF BACKGROUND DATA C2 pedicle screws can be successful anchors for a variety of cervical problems. Standard intraoperative image guidance, biplane fluoroscopy, or free hand techniques all have their drawbacks. METHODS After adequate C2 exposure, the C2 pedicle is palpated. The dissector remains stationary to provide coronal orientation while a lateral C-arm radiograph is obtained for sagittal orientation. The drill trajectory is set, the C2 pedicle cannulated, and a cancellous screw placed. RESULTS A total of 71 patients had bilateral screws placed and 8 patients had unilateral screws placed. The overall complication rate was 2.7%. CONCLUSIONS In our series, we have found a consistent way to cannulate the C2 pedicle. C2 fixation serves as an integral part of cervical reconstruction. Preoperative planning, anatomic knowledge, and lateral C-arm orientation create a low morbidity method for C2 screw placement. |
Databáze: | OpenAIRE |
Externí odkaz: |