Acute type A aortic dissection complicated by aortic stent graft collapse
Autor: | László Daróczi, Kálmán Hüttl, Zoltán Szabolcs, Agnes Laczkó, Erzsébet Paulovich, Tivadar Hüttl, István Hartyánszky |
---|---|
Rok vydání: | 2008 |
Předmět: |
Pulmonary and Respiratory Medicine
Male medicine.medical_specialty medicine.medical_treatment Aortic stent Chest pain Blood Vessel Prosthesis Implantation medicine.artery medicine Humans cardiovascular diseases Collapse (medical) Aortic dissection Aorta business.industry Stent Middle Aged equipment and supplies medicine.disease Surgery Aortic Aneurysm Blood Vessel Prosthesis Prosthesis Failure Aortic Dissection surgical procedures operative Circulatory system Acute Disease Stents Radiology medicine.symptom Cardiology and Cardiovascular Medicine business Complication |
Zdroj: | The Annals of thoracic surgery. 87(4) |
ISSN: | 1552-6259 |
Popis: | A 57-year-old man complaining of chest pain presented with signs of lower limb ischemia 1 year after implantation of a stent graft at the aortoiliac bifurcation. A computed tomography scan revealed the presence of a type A aortic dissection and complete collapse of the stent graft by bulging of the false lumen. The patient underwent emergency surgical reconstruction of the aortic root and arch, which allowed reexpansion of the previously collapsed stent graft. Stenting of residual stenoses distal to the stent graft and of an occluded left renal artery was also successful. |