Multicenter evaluation of Neurelec Digisonic® SP cochlear implant reliability
Autor: | Djamel Djennaoui, Emilien Radafy, Luminiţa Rădulescu, Sebastian Cozma, Nicolas Guevara, I. Gahide, Renaud Meller, Jean-Pierre Bebear, Jean-Pierre Lavieille, Casimir Niemczyk, John Economides, Eric Truy, Philippe Bordure |
---|---|
Rok vydání: | 2012 |
Předmět: |
Adult
Male Reoperation Pediatrics medicine.medical_specialty Current generation Adolescent medicine.medical_treatment Cumulative Survival Rate Prosthesis Design 03 medical and health sciences 0302 clinical medicine Surveys and Questionnaires Cochlear implant Humans Medicine Child 030223 otorhinolaryngology Cochlear implantation Device failure Device Removal Retrospective Studies business.industry Retrospective cohort study General Medicine Cochlear Implantation Survival Analysis Surgery Equipment Failure Analysis Cochlear Implants Otorhinolaryngology Female Neurosurgery business 030217 neurology & neurosurgery |
Zdroj: | European Archives of Oto-Rhino-Laryngology. 270:1507-1512 |
ISSN: | 1434-4726 0937-4477 |
Popis: | Over the past decade, the adoption of universal hearing screening in newborns has led to earlier detection of hearing problems and significant lowering of the age of first cochlear implantation. As a consequence, recipients are now expected to keep their cochlear implants (CIs) for a longer period of time. Comprehensive longitudinal information on CI reliability is essential for device choice. The aim of this study was to assess the reliability (in children and adults) of the latest generation of the Digisonic(®) SP CI launched in 2006 by Neurelec. Failure rate (FR) and cumulative survival rate (CSR) for a 5-year period were calculated. This survey is a multicenter retrospective study. A questionnaire was sent to nine CI centers requesting information about patients implanted with Neurelec Digisonic(®) SP CIs. FR and CSR over a 5-year period were calculated on this group. Collaborating centers collected data on 672 patients (362 children and 310 adults) implanted between March 2006 and March 2011. The overall rate of explantation was 2.23 % (15 cases): six devices were explanted due to device failure (0.89 %) and nine were explanted for medical reasons (1.34 %). Four patients were lost to follow-up. The CSR at 5 years was 98.51 % on all patients, 98.48 % for children and 98.57 % for adults. FR was 0.97 % for adults and 0.83 % for children. This first independent study that assesses FR and CSR on the current generation of Digisonic(®) SP CI represents an important resource that can help clinicians and patients during their device choice. |
Databáze: | OpenAIRE |
Externí odkaz: |