Inter-laboratory comparison of water solubility methods applied to difficult-to-test substances

Autor: Heidi Birch, Philipp Mayer, Aaron D. Redman, Daniel J. Letinski
Rok vydání: 2021
Předmět:
Zdroj: BMC Chemistry
Letinski, D J, Redman, A D, Birch, H & Mayer, P 2021, ' Inter-laboratory comparison of water solubility methods applied to difficult-to-test substances ', BMC Chemistry, vol. 15, no. 1, 52 . https://doi.org/10.1186/s13065-021-00778-7
BMC Chemistry, Vol 15, Iss 1, Pp 1-10 (2021)
ISSN: 2661-801X
Popis: Water solubility is perhaps the single most important physical–chemical property determining the environmental fate and effects of organic compounds. Its determination is particularly challenging for compounds with extremely low solubility, frequently referred to as “difficult-to-test” substances and having solubility’s generally less than 0.1 mg/L. The existing regulatory water solubility test for these compounds is the column elution method. Its applicability, however, is limited, to non-volatile solid or crystalline hydrophobic organic compounds. There currently exists no test guideline for measuring the water solubility of very hydrophobic liquid, and potentially volatile, difficult-to-test compounds. This paper describes a “slow-stir” water solubility methodology along with results of a ring trial across five laboratories evaluating the method’s performance. The slow-stir method was applied to n-hexylcyclohexane, a volatile, liquid hydrophobic hydrocarbon. In order to benchmark the inter-laboratory variability associated with the proposed slow-stir method, the five laboratories separately determined the solubility of dodecahydrotriphenylene, a hydrophobic solid compound using the existing column elution guideline. Results across the participating laboratories indicated comparable reproducibility with relative standard deviations (RSD) of 20% or less reported for each test compound – solubility method pair. The inter-laboratory RSD was 16% for n-hexylcyclohexane (mean 14 µg/L, n = 5) using the slow-stir method. For dodecahydrotriphenylene, the inter-laboratory RSD was 20% (mean 2.6 µg/L, n = 4) using the existing column elution method. This study outlines approaches that should be followed and the experimental parameters that have been deemed important for an expanded ring trial of the slow-stir water solubility method. Supplementary Information The online version contains supplementary material available at 10.1186/s13065-021-00778-7.
Databáze: OpenAIRE