Correlation and Agreement of Yttrium-90 Positron Emission Tomography/Computed Tomography with Ex Vivo Radioembolization Microsphere Deposition in the Rabbit VX2 Liver Tumor Model

Autor: Andrew C. Gordon, Andrew C. Larson, Samdeep K. Mouli, Reed A. Omary, Kent T. Sato, Robert J. Lewandowski, Kathleen R. Harris, Robert K. Ryu, Riad Salem, Vanessa L. Gates, Weiguo Li, Zhuoli Zhang, Sarah B. White, Donald Samaan, J. Nicolai, Daniel Procissi
Rok vydání: 2021
Předmět:
Liver tumor
chemistry.chemical_element
Radiation Dosage
Article
030218 nuclear medicine & medical imaging
Microsphere
Necrosis
03 medical and health sciences
Liver Neoplasms
Experimental

0302 clinical medicine
Predictive Value of Tests
Positron Emission Tomography Computed Tomography
medicine
Animals
Yttrium Radioisotopes
Radiology
Nuclear Medicine and imaging

Positron Emission Tomography-Computed Tomography
medicine.diagnostic_test
business.industry
Magnetic resonance imaging
Yttrium
medicine.disease
Embolization
Therapeutic

Tumor Burden
chemistry
Positron emission tomography
030220 oncology & carcinogenesis
Radiographic Image Interpretation
Computer-Assisted

Female
Rabbits
Radiopharmaceuticals
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Correction for attenuation
Ex vivo
Zdroj: J Vasc Interv Radiol
ISSN: 1051-0443
Popis: PURPOSE: To demonstrate stronger correlation and agreement of (90)Y PET/CT measurements with explant liver tumor dosing compared to the Standard Model (SM) for radioembolization. MATERIALS AND METHODS: Hepatic VX2 tumors were implanted into New Zealand White rabbits with growth confirmed on 7T MRI. Seventeen VX2 rabbits provided 33 analyzed tumors. Treatment volumes were calculated with manually drawn volumes of interest (VOI) with 3D surface renderings. Radioembolization with glass (90)Y microspheres was performed. PET/CT imaging (Siemens Biograph 40) was completed with scatter and attenuation correction. 3D ellipsoid VOI were drawn to encompass tumors on fused images. Tumors and livers were then explanted for inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis of microsphere content. (90)Y PET/CT and SM measurements were compared to reference standard ICP-OES measurements of tumor dosing with Pearson correlation and Bland-Altman analyses for agreement testing with and without adjustment for tumor necrosis. RESULTS: The median infused activity was 33.3 MBq (range, 5.9–152.9). The correlation between (90)Y PET/CT measurements and tumor dose was r=0.903 (p
Databáze: OpenAIRE