Advanced technology of transformer winding condition control based on nanosecond probing impulse

Autor: V. A. Lavrinovich, Hongda Li, Aleksey Vladimirovich Mytnikov
Rok vydání: 2016
Předmět:
Engineering
дефекты
probing impulse
020209 energy
диагностика
frequency range
неисправности
Power transformers
02 engineering and technology
01 natural sciences
lcsh:TD1-1066
law.invention
Impulse generator
зондирующие импульсы
axial and radial shift of turns
law
0103 physical sciences
0202 electrical engineering
electronic engineering
information engineering

Electronic engineering
lcsh:Environmental technology. Sanitary engineering
Transformer
winding defect
010302 applied physics
failure diagnostics
business.industry
импульсные методы
ликвидация
Electric potential energy
Electrical engineering
FRA
General Medicine
Nanosecond
силовые трансформаторы
pulsed method
Transformer windings
power transformers
Power engineering
Electric power industry
business
Short circuit
Zdroj: Resource-Efficient Technologies, Vol 2, Iss 3, Pp 111-117 (2016)
Resource-Efficient Technologies
ISSN: 2405-6537
DOI: 10.1016/j.reffit.2016.07.003
Popis: One of the prospects of resource-effective technologies in power industry is control of electric equipment condition. Effectiveness of any electrical energy system strongly depends on stable work of power supply equipment. It, in turn, is defined by timely and reliable control of equipment condition. Power transformers are the key element of an electrical energy system.Winding defects caused by short circuit currents are the reason for an emergency situation. Reliable control of winding condition is an urgent task of modern power engineering technology. This paper deals with the experimental research of pulsed method of transformer winding control. A new approach to the winding condition control technology is described. The proposed method is based on short nanosecond range (compared to typical pulsed technology) probing impulse andfront impulse durations. Experimental results of sensitivity growth at the nanosecond probing impulse duration are shown. Experimental equipment and measurements are described. Comparison of experimental results of the proposed pulsed method and FRA is given. It is shown that probing impulse of nanosecond duration allows upgrading sensitivity of diagnostics procedure. The main proposals are confirmed by measurement results obtained in the electric energy system transformer for different types of winding defects.
Databáze: OpenAIRE