Underestimation of Nocturnal Hypoxemia Due to Monitoring Conditions in Patients With COPD

Autor: F. Brijker, Frank J.J. van den Elshout, Yvonne F. Heijdra, Hans Th.M. Folgering
Rok vydání: 2001
Předmět:
Male
Pulmonary and Respiratory Medicine
medicine.medical_specialty
Polysomnography
mogelijke oorzaken en gevolgen (sepsis en ontsteking) [Sepsis en niet-bacteriële gegeneraliseerde ontsteking]
Nocturnal
causes and effects (sepsis and inflammation) [Sepsis and non-bacterial generalized inflammation]
Critical Care and Intensive Care Medicine
Time
Hypoxemia
Internal medicine
medicine
Humans
Control mechanisms in asthma and chronic obstructive pulmonary disease
In patient
Lung Diseases
Obstructive

Oximetry
Hypoxia
Aged
Aged
80 and over

COPD
medicine.diagnostic_test
business.industry
Respiratory disease
Middle Aged
medicine.disease
respiratory tract diseases
Pulmonology
Anesthesia
Regulatie mechanismen bij astma en chronisch obstructieve longaandoeningen
Breathing
Physical therapy
Female
medicine.symptom
Cardiology and Cardiovascular Medicine
business
Zdroj: Chest, 119, 1820-6
Chest, 119, 6, pp. 1820-6
ISSN: 0012-3692
DOI: 10.1378/chest.119.6.1820
Popis: Item does not contain fulltext STUDY OBJECTIVES: COPD patients run a risk of developing nocturnal oxygen desaturation. When evaluating patients with nocturnal hypoxemia, an unfamiliar hospital environment and the monitoring equipment may cause sleep disturbances. It was hypothesized that increased sleep disruption will lead to fewer instances of desaturation during a night of monitoring. DESIGN:The following forms of monitoring were evaluated prospectively on 3 nights for each patient: oximetry at home; polysomnography (PSG) at home; and PSG in the hospital. SETTING: Department of Pulmonology, Rijnstate Hospital Arnhem, The Netherlands. PATIENTS: Fourteen stable COPD patients (7 men; median age, 71.5 years; age range, 59 to 81 years; FEV(1), 32.5% predicted; FEV(1) range, 19 to 70% predicted) participated in the study. All subjects had significant instances of nocturnal arterial oxygen desaturation. Those patients with a sleep-related breathing disorder or cardiac failure were excluded from the study. MEASUREMENTS AND RESULTS: The mean nocturnal arterial oxygen saturation (SaO(2)) level was higher during PSG monitoring at home (89.7%; range, 77 to 93%) than during oximetry monitoring (88.5%; range, 80 to 92%) [p < 0.025]. The fraction of time spent in hypoxemia (ie, SaO(2) < 90%) was lower during PSG monitoring at home (40.8%; range, 5 to 100%) than during oximetry monitoring (59.9%; range, 6 to 100%) [p < 0.01]. Desaturation time (DeltaSaO(2) > 4%) was lower during PSG monitoring at home (22.1%; range, 3 to 63%) during PSG monitoring at home than during oximetry monitoring (50.4%; range, 4 to 91%) [p < 0.01]. A correction for actual sleep during PSG monitoring reduced the differences between PSG monitoring at home and oximetry monitoring, although a difference in the desaturation time remained (PSG monitoring at home, 31.9% [range, 2 to 75%]; oximetry monitoring, 50.4% [range, 4 to 91%]) [p = 0.041]. A comparison of sleep architectures for nights when PSG was being monitored showed a higher arousal index in the hospital than at home (PSG monitoring in the hospital, 5.6 arousals per hour [range, 2 to 16 arousals per hour]; PSG monitoring at home, 2.5 arousals per hour [range, 1 to 6 arousals per hour]) [p < 0.025], but no differences in SaO(2) levels were found between PSG monitoring at home and PSG monitoring in the hospital. CONCLUSION: The artifacts due to sleep-monitoring equipment may cause an underestimation of the degree of nocturnal hypoxemia in COPD patients. The addition of an unfamiliar environment causes more sleep disruption, but this does not affect nocturnal SaO(2) levels further.
Databáze: OpenAIRE