Tumor-directed PET imaging of metastases in metastatic castration-resistant prostate cancer (mCRPC) using Zr-89 labeled antiprostate-specific membrane antigen (PSMA) antibody J591
Autor: | Jarett L. Feldman, Michael J. Morris, Danny F. Martinez, Scott T. Tagawa, David M. Nanus, Stephen Barnett Solomon, Jorge A. Carrasquillo, Victor E. Reuter, Jason Stuart Lewis, Joseph A. O' Donoghue, Susan F. Slovin, Dana E. Rathkopf, Mithat Gonen, Volkan Beylergil, Jeremy C. Durack, Sarah M. Cheal, Neil Harrison Bander, Howard I. Scher, Steven M. Larson, Neeta Pandit-Taskar |
---|---|
Rok vydání: | 2015 |
Předmět: | |
Zdroj: | Journal of Clinical Oncology. 33:164-164 |
ISSN: | 1527-7755 0732-183X |
DOI: | 10.1200/jco.2015.33.7_suppl.164 |
Popis: | 164 Background: There is no standard imaging (SI) modality that specifically and accurately images prostate cancer (PC) metastases, hampering prognostication and response assessment. J591 is a humanized antibody that targets the external domain of PSMA. We have previously reported on the feasibility, PK and biodistribution properties of 89Zr-J591 in 10 patients (pts) (Pandit-Taskar et al, Eur J Nuc Med Img 2014). We now report on the targeting/accuracy in 50 pts with mCRPC. Methods: Following standard CT/MRI, bone scan (BS), and FDG PET imaging, 5 mCi of 89Zr-J591 was administered IV. 89Zr-J591 was imaged 6-8 days after injection. Positive (pos) scan findings were confirmed, where possible, with biopsies (bxs) in the following preference: concordant 89Zr-J591 and FDG pos, 89Zr-J591 and FDG mismatch, and a mismatch between SI and any PET. Results: Imaging: A total of 703 lesions in 50 pts were identified using all imaging modalities. Bone:538 total bone lesions were detected. 491(91%) lesions were present on J591 of which 99 were only evident by J591. BS identified 339 (63%), CT 301 (56%), and FDG 207 (38%). Soft Tissue: 165 total soft tissue lesions were detected. 90 (55%) were seen on J591 of which 17 were only evident by J591. CT identified 124 (75%) and FDG 88 (53%). Pathology:46 bx’s were evaluable (21 bone, 25 soft tissue) in 34 pts. Of the unique J591 lesions biopsied (bx’d), 5/7 were pos for PC. Bone: We bx’d 19 J591 pos lesions and 2 J591 neg sites. Overall, path concordance with J591 was: 89% true pos, 100% true neg, 11% false pos, and 0% false neg. Soft tissue: We bx’d 16 J591 pos lesions and 9 J591 neg sites. Of these, we found 88% true pos, 11% true neg, 13% false pos, and 89% false neg. Conclusions: J591 PET identifies additional disease in bone not seen using other imaging modalities. These lesions are highly likely to correspond to disease by bx. However, the tracer performed less well in soft tissue, with a high false neg rate. Clinical trial information: NCT01543659. |
Databáze: | OpenAIRE |
Externí odkaz: |