Cone beam computed tomography cone-beam computed tomography business.industry Anterior cranial imaging 610 Medicine & health General Medicine computer.software_genre Article voxel-based superimposition Voxel Medicine Superimposition three-dimensional anterior cranial base Craniofacial business Nuclear medicine computer Reliability (statistics) |
Zdroj: | Journal of Clinical Medicine Volume 10 Issue 22 Journal of Clinical Medicine, Vol 10, Iss 5429, p 5429 (2021) Ghamri, Mohammed; Kanavakis, Georgios; Gkantidis, Nikolaos (2021). Reliability of Different Anterior Cranial Base Reference Areas for Voxel-Based Superimposition. Journal of clinical medicine, 10(22) MDPI 10.3390/jcm10225429 |
ISSN: | 2077-0383 |
DOI: | 10.3390/jcm10225429 |
Popis: | The study aimed to evaluate the reliability and reproducibility and compare the outcomes of two 3D voxel-based superimposition techniques for craniofacial CBCT images, using anterior cranial base areas of different extent as references. Fifteen preexisting pairs of serial CBCTs (initial age: 11.7 ± 0.6 years interval: 1.7 ± 0.4 years) were superimposed on total anterior cranial base (TACB) or middle anterior cranial base (MACB) structures through the Dolphin 3D software. The overlap of the reference structures was assessed visually to indicate reliability. All superimpositions were repeated by the same investigator. Outcomes were compared to assess the agreement between the two methods. Reliability was perfect for the TACB and moderate for the MACB method (p = 0.044). Both areas showed good overall reproducibility, though in individual cases there were notable differences for MACB superimpositions, ranging from −1.84 to 1.64 mm (TACB range: −0.48 to 0.31 mm). The overall agreement in the detected T0/T1 changes was also good, though it was significantly reduced for individual measurements (median < 0.01 mm, IQR: 0.46 mm, range: −2.81 to 0.73 mm). In conclusion, the voxel-based superimposition on TACB was more reliable and showed higher reproducibility than the superimposition on MACB. Thus, the extended anterior cranial base area is recommended for the assessment of craniofacial changes. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |