Optimal flow pattern for mechanical ventilation of the lungs. 2. The effect of a sine versus square wave flow pattern with and without an end-inspiratory pause on patients
Autor: | C. J. Maffeo, J. F. Dammann, T. C. Mcaslan |
---|---|
Rok vydání: | 1978 |
Předmět: |
Adult
Male medicine.medical_specialty Software_OPERATINGSYSTEMS Software_GENERAL Acoustics medicine.medical_treatment Critical Care and Intensive Care Medicine InformationSystems_GENERAL Sine wave medicine Ventilation-Perfusion Ratio Humans Sine Argon Cardiac Output Intensive care medicine End Inspiratory Pause Aged Mechanical ventilation Clinical Trials as Topic business.industry Optimal flow Hemodynamics Square wave Flow pattern Carbon Dioxide Middle Aged Respiration Artificial ComputingMilieux_GENERAL Oxygen Spirometry Breathing Female Software_PROGRAMMINGLANGUAGES business Pulmonary Ventilation |
Zdroj: | Critical care medicine. 6(5) |
ISSN: | 0090-3493 |
Popis: | In four series of patients, the efficiency of ventilation of a sine wave without an end-inspiratory pause was compared to a square wave without a pause, a sine wave with a pause to a square wave with a pause, a sine wave to a sine wave with a pause, and a sine wave with a long pause to one with a short pause. The primary mode of evaluation was through simultaneous airway and arterial argon washout curves. Additional cardiopulmonary measurements were made. Results indicate: (1) a statistically significant improvement in ventilation with a sine wave with a pause; (2) a statistically significant improvement with the longer pause as compared to the short pause. |
Databáze: | OpenAIRE |