Autor: |
Myron R. Tucker, David E. Frost, William L. Foley, William B. Paulin |
Rok vydání: |
1989 |
Předmět: |
|
Zdroj: |
Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 47(3) |
ISSN: |
0278-2391 |
Popis: |
Multiple techniques of internal screw fixation are being used in clinical oral and maxillofacial surgery. This study evaluated the uniaxial pull-out strength of five commonly used screws and Krischner pins placed by five different techniques. The pull-out strength of the Kirschner pins was significantly less ( P > .0001) than that of the screws. The screw techniques did not differ significantly. |
Databáze: |
OpenAIRE |