POSTAL TLD AUDIT OF HETEROGENEITY CORRECTIONS IN RADIOTHERAPY IN THE CZECH REPUBLIC
Autor: | Daniela Ekendahl, Michaela Kapuciánová |
---|---|
Rok vydání: | 2018 |
Předmět: |
Czech
Quality Control medicine.medical_specialty Quality Assurance Health Care medicine.medical_treatment Relative standard deviation Dose profile Irradiated Volume Dose distribution Audit 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine medicine Humans Radiology Nuclear Medicine and imaging Medical physics Czech Republic Photons Radiation Radiological and Ultrasound Technology business.industry Radiotherapy Planning Computer-Assisted Public Health Environmental and Occupational Health Radiotherapy Dosage General Medicine language.human_language Radiation therapy 030220 oncology & carcinogenesis language Thermoluminescent Dosimetry Thermoluminescent dosimeter Particle Accelerators business |
Zdroj: | Radiation protection dosimetry. 186(2-3) |
ISSN: | 1742-3406 |
Popis: | In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015–2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of 70% of participants complied with the limit of 3% in the first round of this audit. |