Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
Autor: | Brian T. Howard, Birce Onal, Damijan Miklavčič, Matt Martien, Atul Verma, Nicole Kirchhof, Noah Barka, Bor Kos, David E. Haines, Mark G. Stewart, Lars M. Mattison |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
electroporation
pulsed electric field modeling medicine.medical_specialty Vena Cava Superior Swine medicine.medical_treatment Catheter ablation 030204 cardiovascular system & hematology Intracardiac injection Lesion 03 medical and health sciences 0302 clinical medicine Superior vena cava Physiology (medical) Internal medicine catheter ablation Atrial Fibrillation Medicine Animals Humans 030212 general & internal medicine Thrombus business.industry Atrial Fibrillation Ablation Atrial fibrillation Original Articles pulsed field ablation medicine.disease Ablation Stenosis Pulmonary Veins Cardiology cardiovascular system Original Article medicine.symptom Cardiology and Cardiovascular Medicine business Endocardium |
Zdroj: | Journal of Cardiovascular Electrophysiology |
ISSN: | 1540-8167 1045-3873 |
Popis: | Background Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. Methods A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. Results No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. Conclusion PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA. |
Databáze: | OpenAIRE |