Popis: |
BACKGROUND: The purpose of this study was to systematically evaluate the effectiveness and safety of a multi-groove silicone drain in single-port video-assisted thoracoscopic lung cancer surgery and its effect on postoperative serum C-reactive protein (CRP) levels. METHODS: We retrospectively analyzed 122 surgical cases who underwent standard lobectomy and lymph node dissection for primary lung cancer between May 2020 and December 2020. A total of 62 patients received 19-F multi-groove silicone drains (experimental group) and 60 patients received 24-F conventional chest drains (control group). According to the different thoracic drainage approaches, the clinical efficacy in the perioperative period, postoperative complications, and postoperative serum CRP levels were compared between the 2 groups. RESULTS: In this study, thoracic drainage volume, the average visual analog scale (VAS) pain scores in incisions, the rate of primary healing at the site of incisions, and the pulmonary infection rate in the multi-groove silicone drain group were significantly lower than those in the conventional chest drain group (P0.05), and the comparison between the 2 groups showed that the levels of serum CRP in the multi-groove silicone drain group at 72 h after the operation were significantly lower than those in the conventional drain group (P |