Correlation investigation of the brightness of GDE-grams using the methods of computer graphics and direct measurements

Autor: Dobrovolsky, Yu., Prokhorov, H., Diachenko, L., Zukow, W., Babelyuk, V, Popovych, I.
Rok vydání: 2022
Zdroj: Journal of Education, Health and Sport. 12:366-372
ISSN: 2391-8306
Popis: Dobrovolsky Yu., Prokhorov H., Diachenko L., Zukow W., Babelyuk V, Popovych I.. Correlation investigation of the brightness of gde-grams using the methods of computer graphics and direct measurements. Journal of Education, Health and Sport. 2022;12(7):366-372. eISSN 2391-8306. DOI http://dx.doi.org/10.12775/JEHS.2022.12.07.035 https://apcz.umk.pl/JEHS/article/view/JEHS.2022.12.07.035 https://zenodo.org/record/6806836 The journal has had 40 points in Ministry of Education and Science of Poland parametric evaluation. Annex to the announcement of the Minister of Education and Science of December 21, 2021. No. The journal has had 40 points in Ministry of Education and Science of Poland parametric evaluation. Annex to the announcement of the Minister of Education and Science of December 21, 2021. No. 32343. Has a Journal's Unique Identifier: 201159. Scientific disciplines assigned: Physical Culture Sciences (Field of Medical sciences and health sciences); Health Sciences (Field of Medical Sciences and Health Sciences). Punkty Ministerialne z 2019 - aktualny rok 40 punktów. Załącznik do komunikatu Ministra Edukacji i Nauki z dnia 21 grudnia 2021 r. Lp. 32343. Posiada Unikatowy Identyfikator Czasopisma: 201159. Przypisane dyscypliny naukowe: Nauki o kulturze fizycznej (Dziedzina nauk medycznych i nauk o zdrowiu); Nauki o zdrowiu (Dziedzina nauk medycznych i nauk o zdrowiu). © The Authors 2022; This article is published with open access at Licensee Open Journal Systems of Nicolaus Copernicus University in Torun, Poland Open Access. This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author (s) and source are credited. This is an open access article licensed under the terms of the Creative Commons Attribution Non commercial license Share alike. (http://creativecommons.org/licenses/by-nc-sa/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited. The authors declare that there is no conflict of interests regarding the publication of this paper. Received: 20.06.2022. Revised: 20.06.2022. Accepted: 07.07.2022. Correlation investigation of the brightness of gde-grams using the methods of computer graphics and direct measurements 1Dobrovolsky Yu., 1Prokhorov H., 1Diachenko L., 2Zukow W., 3Babelyuk V., 4Popovych I. 1Yuriy Fedkovych Chernivtsi National University, Ukraine 2Nicolaus Copernicus University, Torun’, Poland 3Vivat Hotel and Health Complex, Morshyn, Ukraine 4Bohomolets’ Institute of Physiology of NAS, Kyiv, Ukraine UDC 004.921: 004.9: 535.23:628.98 Abstract There are two methods of measuring the glow of a liquid under the conditions of gas-discharge imaging. This is a investigation of the brightness of GD-grams - a digital image of streamers created under these conditions, and a direct measurement of brightness using a luminometer, which is carried out during the formation of a streamer during a gas discharge. In the first case, the digital image is analyzed using computer graphics methods and certain software. In the second, the results of direct measurement are analyzed. We have analyzed these two methods using the example of the glow of water under the conditions of gas-discharge visualization. It is shown that with direct measurements the brightness values are higher than when investigating the brightness of a digital image of the same streamer obtained in the same time period. Namely 1.5 cd/m2 and 1.7 cd/m2. The difference is 13% and significantly exceeds the measurement error of the brightness meter (± 7%). According to the results of our research, we suggest that, at the very least, when calibrating the devices that create the GDV-grams, use direct measurements of the glow of the liquid in photometric units. For example, in brightness units. Keywords: Gas-discharge visualization, computer graphics, brightness, streamer, digital image
Databáze: OpenAIRE