Intra-aortic balloon pump for combined myocardial contusion and thoracic aortic rupture
Autor: | Ernest E. Moore, Alan R. Hopeman, Mark A. Ammons, Frederick A. Moore |
---|---|
Rok vydání: | 1990 |
Předmět: |
medicine.medical_treatment
Aortic Rupture Contusions Aortic injury Aorta Thoracic Critical Care and Intensive Care Medicine Balloon Counterpulsation medicine Humans Aortic rupture Intra-aortic balloon pump Postoperative Care Intra-Aortic Balloon Pumping business.industry Myocardial contusion Middle Aged medicine.disease Blood Vessel Prosthesis Ventricular failure Heart Injuries Anesthesia cardiovascular system Surgery Female business |
Zdroj: | The Journal of trauma. 30(12) |
ISSN: | 0022-5282 |
Popis: | The coexistence of myocardial contusion and thoracic aortic injury is probably more common than recognized following rapid deceleration multisystem trauma. This report describes the successful application of intra-aortic balloon counterpulsation in a critically injured patient requiring emergent repair of a thoracic aortic tear complicated by ventricular failure due to cardiac contusion. |