Popis: |
SARS-CoV-2 antibody tests are available in various formats, detecting different viral target proteins and antibody subclasses. The specificity and sensitivity of SARS-CoV-2 antibody tests are known to vary and very few studies have addressed the performance of these tests in COVID-19 patient groups at different time points. We here compared the sensitivity and specificity of seven commercial (SNIBE, Epitope, Euroimmun, Roche, Abbott, DiaSorin, Biosensor) and two in-house LIPS assays (LIPS N and LIPS S-RBD) IgG/total Ab tests in serum samples from 97 COVID-19 patients and 100 controls, and correlated the results with the patients' clinical data and the time-point the test was performed. We found a remarkable variation in the sensitivity of antibody tests with the following performance: LIPS N (91.8%), Epitope (85.6%), Abbott and in-house LIPS S-RBD (both 84.5%), Roche (83.5%), Euroimmun (82.5%), DiaSorin (81.4%), SNIBE (70.1%), and Biosensor (64.9%). The overall agreement between the tests was between 71-95%, whereas the specificity of all tests was within 98-100%. The correlation with patients' clinical symptoms score ranged from strongest in LIPS N (ρ = 0.41; p |