The use of Doppler ultrasonography for pre- and post-surgery monitoring of abdominal aortic aneurysm. Case report

Autor: Victorita Stefanescu, Monica Georgescu, Michaela Dobre, Philippe Arbeille
Rok vydání: 2016
Předmět:
Zdroj: Medical Ultrasonography. 18:127
ISSN: 2066-8643
1844-4172
DOI: 10.11152/mu.2013.2066.181.meg
Popis: A 75 year old male patient was monitored for 3 years by Doppler Ultrasonography (US) for an abdominal aorta aneurysm (AAA). Because the aneurysm increased significantly, an aortic prosthesis was installed via an endovascular procedure. After one month of post-surgery monitoring, both Doppler US exam and contrast enhancement US (CEUS) suspected the presence of a leak at the level of the prosthesis. A new surgical procedure was scheduled and intraoperative arteriography confirmed an endoleak type II. Although not always able to specify the correct type of linkage, CEUS remains a reliable method for investigating the postoperative complications of AAA.