Electrochemical assessment of some titanium and stainless steel implant dental alloys

Autor: Carlos Arroyave, A. Echevarría
Jazyk: angličtina
Rok vydání: 2003
Předmět:
lcsh:TN1-997
Espectroscopia de impedancia
Aleaciones de titanio
Materials science
Aleaciones Dentales
Synthetic saliva solution
Alloy
Electrochemical analysis
chemistry.chemical_element
Impedance spectroscopy
engineering.material
Electrochemistry
Materials Chemistry
Immersion (virtual reality)
Titanium alloys
Solución de saliva sintética
Physical and Theoretical Chemistry
Porosity
Análisis electroquímico
lcsh:Mining engineering. Metallurgy
Acero Inoxidable
Dental alloys
Metallurgy
Metals and Alloys
Ringer's solution
Acero inoxidable quirúrgico
Surgical stainless steel
Condensed Matter Physics
Stainless Steel
Dielectric spectroscopy
Ringer's Solution
chemistry
engineering
Aleaciones dentales
Implant
Solución de Ringer
Electrochemical impedance spectroscopy
Titanium
Espectroscopia de impedancia electroquímica
Dental Alloys
Zdroj: Repositorio UdeA
Universidad de Antioquia
instacron:Universidad de Antioquia
Revista de Metalurgia, Vol 39, Iss Extra, Pp 174-181 (2003)
Scopus-Elsevier
Revista de Metalurgia; Vol. 39 No. Extra (2003); 174-181
Revista de Metalurgia; Vol. 39 Núm. Extra (2003); 174-181
Revista de Metalurgia
Consejo Superior de Investigaciones Científicas (CSIC)
ISSN: 1988-4222
0034-8570
DOI: 10.3989/revmetalm.2003.v39.iExtra
Popis: Commercially pure titanium alloy, Ti-6Al-4V alloy and stainless steel screw implants were evaluated in both Ringer and synthetic saliva physiological solutions at body temperature by EIS (Electrochemical Impedance Spectroscopy) with immersion times of 30 d. Results were simulated as a "sandwich system" composed by four capacitors-resistances connected in series with the solution resistance. A model explaining the results in terms of the porosity and thickness of four different layers, was proposed.Se utilizó la técnica de la Espectroscopia de Impedancia Electroquímica para evaluar en soluciones fisiológicas artificiales (Ringer y saliva sintética) muestras extraídas de tornillos de implantes dentales certificados de titanio comercialmente puro, aleación Ti-6Al-W y acero inoxidable a temperatura corporal, con tiempos de inmersión hasta de 30 d. Los resultados se simularon mediante un modelo del tipo sandwich de cuatro elementos RC, conectados en serie con una resistencia de la solución. A partir de de esta simulación, se propone un modelo que explica los resultados obtenidos en términos de la evolución de la porosidad y el espesor de cuatro diferentes capas que se desarrollan en la superficie de los materiales evaluados.