Parametrization and application of scatter kernels for modelling scanned proton beam collimator scatter dose
Autor: | Peter Kimstrand, Nina Tilly, Erik Traneus, Anders Ahnesjö |
---|---|
Rok vydání: | 2008 |
Předmět: |
Monte Carlo method
Radiation computer.software_genre Models Biological The Svedberg Laboratory Collimated light law.invention Optics law Voxel Proton Therapy Scattering Radiation Radiology Nuclear Medicine and imaging Computer Simulation Proton therapy Physics Radiological and Ultrasound Technology business.industry Radiotherapy Planning Computer-Assisted Collimator Radiotherapy Dosage business computer Monte Carlo Method Beam (structure) Algorithms |
Zdroj: | Physics in medicine and biology. 53(13) |
ISSN: | 0031-9155 |
Popis: | Collimators are routinely used in proton radiotherapy to laterally confine the field and improve the penumbra. Collimator scatter contributes up to 15% of the local dose and is therefore important to include in treatment planning dose calculation. We present a method for reconstruction of the collimator scatter phase space based on the parametrization of pre-calculated scatter kernels. Collimator scatter distributions, generated by the Monte Carlo (MC) package GEANT4.8.2, were scored differential in direction and energy. The distributions were then parametrized so as to enable a fast reconstruction by sampling. MC calculated dose distributions in water based on the parametrized phase space were compared to full MC simulations that included the collimator in the simulation geometry, as well as to experimental data. The experiments were performed at the scanned proton beam line at the The Svedberg Laboratory (TSL) in Uppsala, Sweden. Dose calculations using the parametrization of this work and the full MC for isolated typical cases of collimator scatter were compared by means of the gamma index. The result showed that in total 96.7% (99.3%) of the voxels fulfilled the gamma 2.0%/2.0 mm (3.0%/3.0 mm) criterion. The dose distribution for a collimated field was calculated based on the phase space created by the collimator scatter model incorporated into the generation of the phase space of a scanned proton beam. Comparing these dose distributions to full MC simulations, including particle transport in the MLC, yielded that in total for 18 different collimated fields, 99.1% of the voxels satisfied the gamma 1.0%/1.0 mm criterion and no voxel exceeded the gamma 2.6%/2.6 mm criterion. The dose contribution of collimator scatter along the central axis as predicted by the model showed good agreement with experimental data. |
Databáze: | OpenAIRE |
Externí odkaz: |