Calculated neutron energy dependence of the dose-response of large recombination chamber
Autor: | Maciej Maciak, M. A. Gryziński, Katarzyna Tymińska |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Nuclear and High Energy Physics
monte carlo Science Physics::Medical Physics recombination chamber Condensed Matter Physics Neutron temperature 030218 nuclear medicine & medical imaging Nuclear physics 03 medical and health sciences 0302 clinical medicine Nuclear Energy and Engineering 030220 oncology & carcinogenesis Safety Risk Reliability and Quality Waste Management and Disposal Instrumentation ambient absorbed dose Recombination |
Zdroj: | Nukleonika, Vol 64, Iss 4, Pp 117-121 (2019) |
ISSN: | 0029-5922 |
Popis: | A model of REM-2-type chamber was modeled with MCNPX code to study the dose-response to monoenergetic neutrons in wide energy range from thermal to 20 MeV for various compositions of gas in the chamber. The energy dependence of the total dose absorbed in the filling gas was compared with the energy dependence of ambient absorbed dose D*(10) and with experimental data. The results of the studies will be useful for designing new, improved generation of recombination chambers. |
Databáze: | OpenAIRE |