Viscoelastic haemostatic assays in aeromedical transport
Autor: | Alexander Bates, Andrew Donohue, James Winearls, James P. A. McCullough |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.diagnostic_test
business.industry Gold coast Point-of-care testing Reproducibility of Results 030208 emergency & critical care medicine Air Ambulances Blood Coagulation Disorders Maximal amplitude University hospital Hemostatics Thromboelastography Thrombelastography 03 medical and health sciences Thromboelastometry 0302 clinical medicine Clotting time Healthy volunteers Emergency Medicine medicine Humans Prospective Studies 030212 general & internal medicine business Nuclear medicine |
Zdroj: | Emergency Medicine Australasia. 32:786-792 |
ISSN: | 1742-6723 1742-6731 |
DOI: | 10.1111/1742-6723.13510 |
Popis: | Objective To assess the feasibility of using rotational thromboelastometry (ROTEM®)-sigma and thromboelastography (TEG®)-6s viscoelastic point-of-care assays during rotary wing aeromedical transport, and to determine the reliability of the results obtained. Methods A single centre, prospective, observational, non-interventional feasibility study performed at Gold Coast University Hospital intensive care unit, and in a LifeFlight Retrieval Medicine operated Leonardo AW139 helicopter. Blood was collected from eight healthy volunteers on 18 April 2019 and all testing was performed on that day. Functions measured were ROTEM-sigma extrinsically activated thromboelastometry (EXTEM) clotting time (CT), EXTEM amplitude at 5 min after CT (A5) and fibrin-based extrinsically activated thromboelastometry (FIBTEM) A5, and TEG-6s Kaolin (CK) reaction time (R), functional fibrinogen (CFF) maximal amplitude (MA) and CFF amplitude at 10 min after R (A10). Differences between the results obtained in the helicopter and control results at Gold Coast University Hospital during flight and after flight, and also differences in control results over time up to 3 h were analysed. Results During flight both the ROTEM-sigma and TEG-6s devices failed to give reliable results. Post flight, the helicopter and control samples correlated well. Repeat testing of control samples at 1 and 3 h also revealed good correlation over time. Conclusion It is feasible to reliably run tests on both the ROTEM-sigma and TEG-6s after the devices have been flown in a rotary wing aircraft. However, testing cannot be performed while in flight conditions. It is also possible to run blood samples collected up to 3 h prior and acquire results which correlate well with initial testing. |
Databáze: | OpenAIRE |
Externí odkaz: |