Extended Sandwich Patch Technique via Right Ventriculotomy for Acute Ventricular Septal Rupture
Autor: | Kohei Hachiro, Tomoaki Suzuki, Tohru Asai, Takeshi Kinoshita |
---|---|
Rok vydání: | 2022 |
Předmět: |
Pulmonary and Respiratory Medicine
medicine.medical_specialty Heart Ventricles Myocardial Infarction Inferior vena cava Ventriculotomy law.invention Ventricular Septal Rupture law medicine Cardiopulmonary bypass Humans Myocardial infarction Cardiac Surgical Procedures Surgical repair business.industry medicine.disease Surgery medicine.anatomical_structure medicine.vein Echocardiography Ventricle Cardiology and Cardiovascular Medicine business Shunt (electrical) |
Zdroj: | The Annals of Thoracic Surgery. 113:1200-1207 |
ISSN: | 0003-4975 |
DOI: | 10.1016/j.athoracsur.2021.04.090 |
Popis: | Background:Surgical repair for postinfarction ventricular septal rupture (VSR) was still a challenging operation, especially when required in the acute phase or posterior VSR. The extended sandwich patch technique is characterized by large double patches fixed by circumferential transmural large mattress sutures via right ventricle incision. In the present study, we report early and midterm clinical and echocardiographic outcomes of this technique. Methods:Of 33 consecutive patients undergoing VSR repair using the extended sandwich patch technique between 2008 and 2018, 25 received surgery within 1 week from the onset of myocardial infarction (early group) and 8 received surgery after 1 week (late group), including 12 patients with posterior VSR. All patients underwent surgery within 24 hours of VSR diagnosis. Results:Intraoperative transesophageal echocardiography identified no residual shunt, but 2 patients received reoperative VSR repair at 9 days and 2 months after the first VSR repair. The 30-day mortality and 1-year survival in the early and late groups were 20% and 12.5%, and 58% and 88%, respectively. After VSR repair, right and left heart chamber sizes were significantly decreased, and these improvements were stable throughout the subsequent follow-up period (median 4.0 years). Tricuspid annular plane systolic excursion and right ventricular fractional area change remained constant throughout the observation period without changing after VSR repair. Conclusions:The extended sandwich patch technique through a right ventriculotomy offered safe and simple, leak-free repair even in technically demanding acute phase or posterior VSR. No significant decline was found in the right heart function after surgery. |
Databáze: | OpenAIRE |
Externí odkaz: |