Fixation of Regan-Morrey Type II Coronoid Fractures: A Comparison of Screws and Suture Lasso Technique for Resistance to Displacement
Autor: | Adrian G. Paez, Michael S. Murphy, Nicholas P. Iannuzzi, Brent G. Parks |
---|---|
Rok vydání: | 2016 |
Předmět: |
musculoskeletal diseases
medicine.medical_specialty medicine.medical_treatment Elbow Bone Screws Osteotomy Screw fixation 03 medical and health sciences Fracture Fixation Internal 0302 clinical medicine Load to failure Elbow Joint Materials Testing medicine Cadaver Humans Orthopedics and Sports Medicine 030212 general & internal medicine Orthodontics Fibrous joint 030222 orthopedics Universal testing machine business.industry Suture Techniques Stiffness equipment and supplies musculoskeletal system Ulna Fractures Surgery Biomechanical Phenomena Equipment Failure Analysis surgical procedures operative medicine.anatomical_structure medicine.symptom Cadaveric spasm business Elbow Injuries |
Zdroj: | The Journal of hand surgery. 42(1) |
ISSN: | 1531-6564 |
Popis: | Purpose The aim of this study was to compare the load to failure and stiffness achieved in coronoid fractures treated with a posterior-to-anterior screw versus a suture lasso technique. Methods We performed a biomechanical study using 10 pairs of fresh-frozen cadaveric elbows. A transverse osteotomy at the midpoint of the coronoid height was created to simulate a Regan–Morrey type II coronoid fracture. The specimens were randomized to screw fixation or suture lasso fixation. The load to failure and stiffness were then measured using a materials testing machine. Results Screw fixation provided greater strength and stiffness than suture lasso fixation. Mean load to failure was 405 N in the screw fixation group compared with a load to failure of 207 N for suture fixation. Screw fixation resulted in a mean stiffness of 284 kPa/mm compared with 119 kPa/mm after suture fixation. Conclusions Screw fixation was biomechanically superior to fixation using a suture lasso technique. For coronoid fractures in which screw or suture fixation is feasible, screw fixation may provide greater resistance to displacement of the coronoid compared with a suture lasso technique. Clinical relevance Clinical studies have reported a higher rate of failure after screw fixation compared with suture lasso fixation; however, this study demonstrated a greater stiffness and load to failure after screw fixation of type II coronoid fractures. Screw fixation may provide a stronger fixation construct for fractures of adequate size to support a screw. Further studies may be warranted to assess the importance of securing the anterior capsule to the coronoid tip when using a suture lasso construct because this may affect the stability of the elbow after fixation. |
Databáze: | OpenAIRE |
Externí odkaz: |