The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens
Autor: | Kjell Gundersen, Richard Potvin |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
Visual acuity genetic structures medicine.medical_treatment Emmetropia Intraocular lens Spherical equivalent Ocular dominance Near vision Ophthalmology Medicine Original Research extended depth of focus business.industry Significant difference Clinical Ophthalmology Presbyopia medicine.disease eye diseases extended vision cataract presbyopia sense organs non-diffractive medicine.symptom business |
Zdroj: | Clinical Ophthalmology (Auckland, N.Z.) |
ISSN: | 1177-5483 1177-5467 |
Popis: | Kjell G Gundersen,1 Richard Potvin2 1IFocus Ãyeklinikk AS, Haugesund, Norway; 2Science in Vision, Bend, OR, USACorrespondence: Kjell G Gundersen Email kg@ifocus.noPurpose: To quantify the changes in the binocular defocus curve associated with the Vivity⢠non-diffractive extended vision intraocular lens when the dominant eye was targeted for emmetropia and the non-dominant eye was artificially targeted for slight myopia using spectacles.Patients and Methods: This was a non-interventional research study of the corrected binocular defocus curve associated with binocular emmetropia (Setting A) and with emmetropia in the dominant eye and two different levels of myopia simulated in the non-dominant eye (â 0.50 D, Setting B and â 1.00 D, Setting C). Subjects were patients implanted with the AcrySof® IQ Vivity® intraocular lens in both eyes 3 to 12 months previously. Using the defocus data, the percentage of subjects with a continuous 2.5 D range of vision (distance to 40 cm) was calculated for various levels of minimum visual acuity (VA).Results: Forty subjects were enrolled. The mean spherical equivalent refraction was â 0.06 D ± 0.36 D, with 0.37 D ± 0.29 D of refractive cylinder. There was no statistically significant difference in the mean VA at â 0.25 D or at â 0.50 D vergences between the test Settings, but there was a statistically significant difference at all other vergences. Differences were particularly noticeable at â 2.00 D, â 2.50 D and â 3.00 D, where higher myopia in the non-dominant eye yielded better binocular VA. A 2.5 D range of functional vision (20/25) was achieved by 38% of subjects at Setting A, 68% of subjects at Setting B and 85% of subjects at Setting C. At setting C, all but one subject (39/40, 97.5%) had a 2.5 D range of vision with a VA of 20/32 or better.Conclusion: Significant gains in binocular near vision, with only a nominal effect on distance vision, can be achieved with the Vivity IOL by leaving the non-dominant eye of patients with 0.50 D or 1.00 D of myopia.Keywords: non-diffractive, extended vision, extended depth of focus, presbyopia, cataract |
Databáze: | OpenAIRE |
Externí odkaz: |