Test of large area glass RPCs at the DAΦNE Test Beam Facility (BTF)

Autor: A. Tonazzo, L. Satta, P. Patteri, S. Ragazzi, M. Piccolo, A. Calcaterra, G. Mannocchi, P.P. Trapani, P. Picchi, D. Gamba, R. de Sangro, N. Redaelli, Gian Carlo Trinchero, T. Tabarelli de Fatis
Přispěvatelé: Calcaterra, A, De Sangro, R, Gamba, D, Mannocchi, G, Patteri, P, Picchi, P, Piccolo, M, Ragazzi, S, Redaelli, N, Satta, L, TABARELLI DE FATIS, T, Tonazzo, A, Trapani, P, Trinchero, G
Rok vydání: 2004
Předmět:
Zdroj: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 533:154-158
ISSN: 0168-9002
Popis: The CaPiRe program has been started to develop a new detector design, in order to produce large areas of glass Resistive Plate Chambers (RPC) detectors, overcoming the previous limitations. As a first step we produced our glass RPC detectors ( 1 m 2 ) at General Tecnica exploiting their standard procedures, materials and production techniques simply using 2 mm glass electrodes instead of the bakelite ones. A set of RPC was produced by using pre-coated (silk screen printed) electrodes, while others were produced with the standard graphite coating. All the detectors, together with four old Glass RPC acting as reference, were tested at the DA Φ NE Test Beam Facility with 500 MeV electrons in order to study the efficiency in different positions inside the detectors (i.e. near spacers and edges) and to study the detector behavior as a function of the local particle rate.