Intra- and inter-rater reliability of joint range of motion tests using tape measure, digital inclinometer and inertial motion capturing
Autor: | Fraeulin, Laura, Holzgreve, Fabian, Brinkbäumer, Mark, Dziuba, Anna, Friebe, David, Klemz, Stefanie, Schmitt, Marco, Theis A., Anna-Lena, Tenberg, Sarah, Mark, Anke van, Maurer-Grubinger, Christian, Ohlendorf, Daniela |
---|---|
Rok vydání: | 2020 |
Předmět: |
Adult
Male Computer and Information Sciences Kinematics Inertia Science Hands Pelvis Computer Software Young Adult Motion Skeletal Joints Medicine and Health Sciences Humans ddc:610 Prospective Studies ddc:796 Range of Motion Articular Physical Examination Musculoskeletal System Skeleton Observer Variation Hip Physics Classical Mechanics Biology and Life Sciences Software Engineering Biomechanical Phenomena Arms Athletic & outdoor sports & games Shoulders Body Limbs Physical Sciences Medicine Engineering and Technology Female Anatomy Research Article |
Zdroj: | PLoS ONE PLoS ONE, Vol 15, Iss 12, p e0243646 (2020) PLOS ONE, 15 (12), e0243646 |
ISSN: | 1932-6203 |
Popis: | Background In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM). Methods Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements. Findings Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81). Interpretation Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices. |
Databáze: | OpenAIRE |
Externí odkaz: | |