Doppler miniprobe to measure arterial graft flow in coronary artery bypass grafting
Autor: | Shoichi Furuta, Hisayoshi Suma, Takayama T, Eiichi Tohda, Matsunaka Toshiyuki, Yasuhiko Wanibuchi, Shoichi Yamashita |
---|---|
Rok vydání: | 1991 |
Předmět: |
Pulmonary and Respiratory Medicine
medicine.medical_specialty Gastroepiploic Artery Internal thoracic artery Anastomosis symbols.namesake Coronary circulation Coronary Circulation medicine.artery Internal medicine medicine Humans Vascular Patency Coronary Artery Bypass Ultrasonography business.industry Blood flow surgical procedures operative medicine.anatomical_structure symbols Cardiology Surgery Radiology Cardiology and Cardiovascular Medicine business Doppler effect Artery |
Zdroj: | The Annals of Thoracic Surgery. 52:322-324 |
ISSN: | 0003-4975 |
DOI: | 10.1016/0003-4975(91)91369-7 |
Popis: | Using a 5 x 5-mm ultrasonographic Doppler miniprobe, the flow volume of arterial grafts (internal thoracic artery and gastroepiploic artery) was measured four times during the course of coronary artery bypass grafting. Graft flow just before sternal closure was almost equivalent to that in the preoperative phase when the anastomosis was optimal. Use of the Doppler miniprobe facilitated evaluation of the arterial graft flow pattern easily and quickly. We conclude that the Doppler miniprobe can provide helpful information for the evaluation of results of coronary artery bypass grafting in real time without necessitating any additional procedures. (Ann Thorac Surg 1991;52:3224) |
Databáze: | OpenAIRE |
Externí odkaz: |