Comparison of bronchial hygiene techniques in mechanically ventilated patients: a randomized clinical trial

Autor: Gracieli Nadalon Deponti, Luciane de Fraga Gomes Martins, Bruno Barcelos Herve, Silvia Regina Rios Vieira, Fernando Nataniel Vieira, Wagner da Silva Naue, Alexandre Simões Dias
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Male
Bronchoalveolar lavage
medicine.medical_specialty
Time Factors
Critical Illness
medicine.medical_treatment
media_common.quotation_subject
Bronchial hygiene
MEDLINE
Hemodynamics
Hyperinflation
Suction
Critical Care and Intensive Care Medicine
law.invention
Hospitals
University

03 medical and health sciences
0302 clinical medicine
Tracheal aspiration
Randomized controlled trial
Hygiene
law
Ventilators
mechanical

Internal medicine
medicine
Humans
030212 general & internal medicine
Letters to the Editor
Aged
media_common
Mechanical ventilation
business.industry
Physical therapy modalities
Ventilatory mechanics
Insufflation
General Medicine
Original Articles
Middle Aged
Respiration
Artificial

Intensive care unit
Intensive Care Units
030228 respiratory system
Anesthesia
Respiratory aspiration
Female
business
Zdroj: Revista Brasileira de Terapia Intensiva
Repositório Institucional do Centro Universitário La Salle
Universidade La Salle (UNILASALLE)
instacron:UNILASALLE
ISSN: 1982-4335
0103-507X
Popis: To compare the effects of vibrocompression and hyperinflation with mechanical ventilator techniques alone and in combination (hyperinflation with mechanical ventilator + vibrocompression) on the amount of aspirated secretion and the change in hemodynamic and pulmonary parameters.A randomized clinical trial with critically ill patients on mechanical ventilation conducted in the intensive care unit of a university hospital. The patients were randomly allocated to receive one of the bronchial hygiene techniques for 10 minutes (vibrocompression or hyperinflation with mechanical ventilator or hyperinflation with mechanical ventilator + vibrocompression). Afterwards, the patients were again randomly allocated to receive either the previous randomly allocated technique or only tracheal aspiration. The weight of aspirated secretions (in grams), ventilatory mechanics and cardiopulmonary data before and after the application of the techniques were analyzed. The tracheal reintubation frequency and time and mortality on mechanical ventilation were also evaluated.A total of 93 patients (29 vibrocompression, 32 hyperinflation with mechanical ventilator and 32 hyperinflation with mechanical ventilator + vibrocompression) on mechanical ventilation for more than 24 hours were included. The hyperinflation with mechanical ventilator + vibrocompression group was the only one that presented a significant increase in aspirated secretions compared to tracheal aspiration alone [0.7g (0.1 - 2.5g) versus 0.2g (0.0 - 0.6g), p value = 0.006].Compared to tracheal aspiration alone, the combination of hyperinflation with mechanical ventilator + vibrocompression techniques was most efficient for increasing the amount of aspirated secretions.Comparar a eficiência das técnicas de vibrocompressão e hiperinsuflação com ventilador mecânico de forma isolada e a associação das duas técnicas (hiperinsuflação com ventilador mecânico + vibrocompressão), na quantidade de secreção aspirada e na alteração de parâmetros hemodinâmicos e pulmonares.Ensaio clínico randomizado com pacientes críticos em ventilação mecânica, realizado na unidade de terapia intensiva de um hospital universitário. Os pacientes foram randomizados para receber uma das técnicas de higiene brônquica por 10 minutos (vibrocompressão, ou hiperinsuflação com ventilador mecânico, ou hiperinsuflação com ventilador mecânico + vibrocompressão). Após, foram novamente randomizados para receber inicialmente a técnica (previamente randomizada) ou apenas a aspiração isolada. Foram analisados o peso de secreção aspirada (em gramas), dados de mecânica ventilatória e cardiopulmonares, antes e após a aplicação das técnicas. A frequência de reintubação traqueal, o tempo de ventilação mecânica e a mortalidade, também foram avaliados.Foram incluídos 93 pacientes (29 vibrocompressão, 32 hiperinsuflação com ventilador mecânico e 32 hiperinsuflação com ventilador mecânico + vibrocompressão) em ventilação mecânica por mais de 24 horas. O grupo hiperinsuflação com ventilador mecânico + vibrocompressão foi o único que apresentou aumento significativo da secreção aspirada, quando comparado a aspiração isolada 0,7g (0,1 - 2,5g) versus 0,2g (0,0 - 0,6g), com valor de p = 0,006.Quando comparada à aspiração isolada, a associação das técnicas hiperinsuflação com ventilador mecânico + vibrocompressão foi mais eficiente na quantidade de secreção aspirada.
Databáze: OpenAIRE