REMOVAL OF POSTERIOR SEGMENT RETAINED LENS MATERIAL USING THE OZIL PHACOEMULSIFICATION HANDPIECE VERSUS FRAGMATOME DURING PARS PLANA VITRECTOMY
Autor: | Marc J. Spirn, Allen Y.H. Hu, R. Gary Lane, Carl D. Regillo, Rayan A. Alshareef, Steven D. Schwartz, Allen Chiang, Sunir J. Garg, John D. Pitcher, Allen C. Ho, Jason Hsu |
---|---|
Rok vydání: | 2012 |
Předmět: |
Male
Pars plana medicine.medical_specialty Time Factors Visual acuity genetic structures medicine.medical_treatment Visual Acuity Vitrectomy Postoperative Complications Ophthalmology Lens Crystalline medicine Humans Intraoperative Complications Aged Retrospective Studies Aged 80 and over Phacoemulsification business.industry Ultrasound Retinal detachment Posterior Eye Segment General Medicine Lens Subluxation Middle Aged medicine.disease eye diseases Posterior segment of eyeball medicine.anatomical_structure Lens (anatomy) Female sense organs medicine.symptom business |
Zdroj: | Retina. 32:2119-2126 |
ISSN: | 0275-004X |
DOI: | 10.1097/iae.0b013e31825a89c3 |
Popis: | PURPOSE To assess the utility of the torsional phacoemulsification handpiece compared to the Fragmatome during pars plana vitrectomy for removal of posterior segment retained lens material. DESIGN : Retrospective comparative case series. METHODS Thirty-four eyes of 34 patients at 2 centers who underwent pars plana vitrectomy for retained lens material with either torsional phacoemulsification or the Fragmatome were retrospectively reviewed. Lens material was graded by nuclear density and percentage of total nuclear size. The primary outcome measure was mean change in visual acuity. Secondary outcomes included intraoperative or postoperative complications, occurrence of mechanical malfunctions and metric data including the total ultrasound, phacoemulsification, and torsional times. RESULTS In the torsional ultrasound group (17 eyes), mean nuclear density was 3.6 and mean size was 63%. Mean initial logarithm of minimum angle of resolution visual acuity was 1.58 (20/760) and improved to 0.66 (20/80) at postoperative Month 3, a gain of 0.92 (P = 0.003). One eye developed a self-limited, peripheral, serous, choroidal detachment intraoperatively, whereas two eyes developed postoperative cystoid macular edema. Mean total ultrasound, phacoemulsification, and torsional times were 76.7, 13.4, and 63.3 seconds, respectively. Mean total operative time to remove retained lens material (excluding vitreous gel removal) was 111 seconds. All the patients demonstrated excellent followability based on independent observations by the surgeons. In the Fragmatome group (17 eyes), initial logarithm of minimum angle of resolution visual acuity was 1.51 (20/640) and improved to 0.6 (20/80) at postoperative Month 3, a gain of 0.91 (P < 0.001). One eye developed a retinal detachment at postoperative Week 2, whereas 3 eyes developed postoperative cystoid macular edema. CONCLUSION The use of torsional phacoemulsification during pars plana vitrectomy for retained lens material is a novel approach with potential advantages over the standard 20-gauge Fragmatome, including improved followability and purchase of lens material attributable to the addition of torsional movement. |
Databáze: | OpenAIRE |
Externí odkaz: |