Characterization of a modified gold platform for the development of a label-free anti-thrombin aptasensor

Autor: Cédric Goyer, Pierre Labbe, Marcela C. Rodríguez, Eric Defrancq, Liliane Coche-Guérente, Yamile Jalit, Galina V. Dubacheva, Gustavo A. Rivas, Fabiana Gutierrez
Přispěvatelé: Laboratoire d'Electrochimie Moléculaire (LEM (UMR_7591)), Université Paris Diderot - Paris 7 (UPD7)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), Département de Chimie Moléculaire - Ingéniérie et Intéractions BioMoléculaires (DCM - I2BM), Département de Chimie Moléculaire (DCM), Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)-Université Joseph Fourier - Grenoble 1 (UJF)-Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)-Université Joseph Fourier - Grenoble 1 (UJF), Université Paris Diderot - Paris 7 (UPD7)-Centre National de la Recherche Scientifique (CNRS), Université Joseph Fourier - Grenoble 1 (UJF)-Centre National de la Recherche Scientifique (CNRS)-Université Grenoble Alpes (UGA)-Université Joseph Fourier - Grenoble 1 (UJF)-Centre National de la Recherche Scientifique (CNRS)-Université Grenoble Alpes (UGA)
Jazyk: angličtina
Rok vydání: 2013
Předmět:
Streptavidin
Conductometry
Optical aptasensor
Aptamer
Biomedical Engineering
Biophysics
Nanotechnology
Thrombin biosensor
Biosensing Techniques
02 engineering and technology
Thrombin binding aptamer
Sensitivity and Specificity
01 natural sciences
chemistry.chemical_compound
Thrombin
Electrochemistry
medicine
Humans
[CHIM]Chemical Sciences
Protein detection
Bovine serum albumin
Surface plasmon resonance
SPR sensing
ComputingMilieux_MISCELLANEOUS
Immunoassay
biology
Chemistry
Otras Ciencias Químicas
010401 analytical chemistry
Ciencias Químicas
Reproducibility of Results
Aptasensor
Equipment Design
General Medicine
Quartz crystal microbalance
Aptamers
Nucleotide

021001 nanoscience & nanotechnology
Combinatorial chemistry
0104 chemical sciences
Equipment Failure Analysis
Biotinylation
biology.protein
Blood Coagulation Tests
0210 nano-technology
Biosensor
CIENCIAS NATURALES Y EXACTAS
Biotechnology
medicine.drug
Zdroj: Biosensors and Bioelectronics
Biosensors and Bioelectronics, Elsevier, 2013, 41, pp.424-429. ⟨10.1016/j.bios.2012.08.061⟩
ISSN: 0956-5663
Popis: This work reports the characterization of a modified gold surface as a platform for the development of a label free aptasensor for thrombin detection. The biorecognition platform was obtained by the self-assembly of 4-mercaptobenzoic acid onto a gold surface, covalent attachment of streptavidin and further immobilization of the biotinylated anti-thrombin aptamer. The biosensing platform was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring. The biorecognition event aptamer-thrombin was detected from changes in the SPR angle produced as a consequence of the molecular interaction between the aptasensor and the target protein. The biosensing platform demonstrated to be highly selective for human thrombin even in the presence of large excess of bovine thrombin, bovine serum albumin, cytochrome C, lysozyme and myoglobin. The relationship between the changes in the SPR angle and thrombin concentration was linear up to 0.19 μmol L−1 (R2=0.992) while the detection limit was of 12.0 nmol L−1 (240 fmol in the sample). This new sensing approach represents an interesting and promising alternative for the SPR-based quantification of thrombin. Fil: Jalit, Yamile. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Dubacheva, Galina. Universite Joseph Fourier; Francia Fil: Goyer, Cedric. Universite Joseph Fourier; Francia Fil: Coche Guerente, Liliane. Universite Joseph Fourier; Francia Fil: Defrancq, Eric. Universite Joseph Fourier; Francia Fil: Labbe, Pierre. Universite Joseph Fourier; Francia Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Rodriguez, Marcela Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina