Measurement of myocardial fractional flow reserve during coronary angioplasty in patients with old myocardial infarction
Autor: | Yasuhide Nakashima, Etsuro Himeno, Shinjou Sonoda, Masaaki Takeuchi, Akio Kuroiwa |
---|---|
Rok vydání: | 1997 |
Předmět: |
Adult
Male medicine.medical_specialty medicine.medical_treatment Myocardial Infarction Hyperemia Constriction Pathologic Coronary Angiography Coronary artery disease Coronary Circulation Internal medicine Angioplasty medicine.artery medicine Humans Myocardial infarction Angioplasty Balloon Coronary Aged medicine.diagnostic_test business.industry Hemodynamics Mean Aortic Pressure Blood flow Middle Aged medicine.disease Coronary Vessels Stenosis Right coronary artery Angiography Cardiology Female Stents Cardiology and Cardiovascular Medicine business |
Zdroj: | Catheterization and Cardiovascular Diagnosis. 42:19-25 |
ISSN: | 1097-0304 0098-6569 |
Popis: | Although myocardial fractional flow reserve (FFRmyo) has been demonstrated to be a useful index for determining functional significance of coronary stenosis, the data in previous studies was derived from a highly selected group of patients. The aim of this study was to investigate the value of FFRmyo in a more clinically relevant group of patients, especially in patients who also had resistance vessel dysfunction. We measured FFRmyo in 20 consecutive patients who had undergone elective coronary angioplasty. FFRmyo was calculated by the ratio of Pc/Pa during intracoronary adenosine 5'-triphosphate (ATP; 50 micrograms in the left coronary and 20 micrograms in the right coronary artery) induced maximal hyperemia, where Pa represents mean aortic pressure obtained by the guiding catheter and Pc represents mean distal coronary pressure measured by a 2.1 F infusion catheter. In total, 21 vessels were dilated and 14 of them were infarct-related arteries. The percent diameter stenosis significantly decreased from 80 +/- 14% to 27 +/- 17%, and the FFRmyo increased significantly from 0.46 +/- 0.18 to 0.77 +/- 0.15 after angioplasty. There was no significant differences in the FFRmyo between vessels with previous myocardial infarction and those without, after angioplasty (0.78 +/- 0.18 vs. 0.76 +/- 0.08). There was a significant correlation between the percent diameter stenosis and FFRmyo before (r = 0.83, P < 0.001) and after (r = 0.64, P < 0.01) angioplasty. In conclusion, FFRmyo significantly improved immediately after angioplasty in vessels with myocardial infarction as well as those without. These results led us to suggest the usefulness of FFRmyo in patients who had both epicardial stenosis and resistance vessel dysfunction. The significant correlation between FFRmyo and quantitative coronary arterial diameter stenosis would further support the more widespread use of FFRmyo in the clinical setting. |
Databáze: | OpenAIRE |
Externí odkaz: |