Quantification of beat-to-beat variability of action potential durations in Langendorff-perfused mouse hearts

Autor: Tse, Gary, Du, Yi-Mei, Chan, Yin Wah Fiona, Liu, Tong, Li, Guangping, Bazoukis, George, Letsas, Konstantinos, Wu, William K, Tian, Xiao Yu, Wong, Wing T, Chang, C-H
Přispěvatelé: Apollo - University of Cambridge Repository
Rok vydání: 2018
Předmět:
Popis: Beat-to-beat variability in action potential duration (APD) is an intrinsic property of cardiac tissue and is altered in pro-arrhythmic states. However, it has never been examined in mice. Methods: Left atrial or ventricular monophasic action potentials (MAPs) were recorded from Langendorff-perfused mouse hearts during regular 8 Hz pacing. Time-domain, frequency-domain and non-linear analyses were used to quantify APD variability. Results: Mean atrial APD (90% repolarization) was 26.6±3.8 ms and standard deviation (SD) was 1.4±0.8 ms (n=6 hearts). Coefficient of variation (CoV) was 5.9±3.2% and root mean square (RMS) of successive differences in APDs was 0.5±0.2 ms. The peaks for low- and high-frequency were 0.8±0.6 and 2.7±1.1 Hz, respectively, with percentage powers of 37.8±14.5 and 61.5±15.1%. Poincaré plots of APDn+1 against APDn revealed ellipsoid shapes. The ratio of the SD along the line-of-identity (SD2) to the SD perpendicular to the line-of-identity (SD1) was 5.96±1.44. Approximate and sample entropy were 0.45±0.05 and 0.54±0.11, respectively. Detrended fluctuation analysis revealed short- and long-term fluctuation slopes of 1.73±0.17 and 0.68±0.20, respectively. When compared to atrial APDs, ventricular APDs were longer (ANOVA, P