Use of tandem stents for treatment of helicoidal dissection of the right coronary artery
Autor: | Franco Júnior Vr, Domingues Ce, Salvadori Júnior D, de Almeida Mc, Furukawa Mk |
---|---|
Rok vydání: | 2000 |
Předmět: |
lcsh:Diseases of the circulatory (Cardiovascular) system
medicine.medical_specialty medicine.medical_treatment Coronary Disease Dissection (medical) Total occlusion Lesion medicine.artery Angioplasty Internal medicine medicine Humans Angioplasty Balloon Coronary business.industry Middle Aged medicine.disease Coronary Vessels Surgery Lumen Diameter Aortic Dissection lcsh:RC666-701 Right coronary artery Cardiology Female Stents medicine.symptom Cardiology and Cardiovascular Medicine business Coronary dissection |
Zdroj: | Arquivos Brasileiros de Cardiologia, Vol 74, Iss 6, Pp 516-518 (2000) |
ISSN: | 0066-782X |
DOI: | 10.1590/s0066-782x2000000600004 |
Popis: | Coronary dissection occurs frequently and in several degrees during coronary angioplasty, which is one of the mechanisms for increasing the lumen diameter of a vessel. However the length of the dissection may affect the procedure, becoming the most frequent cause of total occlusion after coronary angioplasty. We report here a case of extensive dissection that occurred during the coronary angioplasty of a focused lesion, which we treated with two long stents. |
Databáze: | OpenAIRE |
Externí odkaz: |