An X-ray harmonic separator for next-generation synchrotron X-ray sources and X-ray free-electron lasers
Autor: | Makina Yabashi, Shunji Goto, Taito Osaka, Haruhiko Ohashi, Hiroshi Yamazaki, Kenji Tamasaku, Ichiro Inoue |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2018 |
Předmět: |
0301 basic medicine
030103 biophysics Nuclear and High Energy Physics Astrophysics::High Energy Astrophysical Phenomena Physics::Optics Radiation 01 natural sciences law.invention SACLA 03 medical and health sciences Optics law 0103 physical sciences harmonic separation 010306 general physics Instrumentation Physics business.industry Undulator Laser Research Papers Synchrotron harmonic radiation diffraction-limited storage rings Harmonics Harmonic Physics::Accelerator Physics X-ray free-electron lasers Prism business |
Zdroj: | Journal of Synchrotron Radiation |
ISSN: | 1600-5775 0909-0495 |
Popis: | A new optical technique used to extract a specific harmonic of undulator radiation is proposed and the concept was experimentally confirmed using X-ray pulses from SACLA. An X-ray prism for the extraction of a specific harmonic of undulator radiation is proposed. By using the prism in a grazing incidence geometry, the beam axes of fundamental and harmonics of undulator radiation are separated with large angles over 10 µrad, which enables the selection of a specific harmonic with the help of apertures, while keeping a high photon flux. The concept of the harmonic separation was experimentally confirmed using X-ray beams from the X-ray free-electron laser SACLA. |