A rapid, simple and sensitive liquid chromatography tandem mass spectrometry assay to determine amoxicillin concentrations in biological matrix of little volume
Autor: | Fiordiligie Casilag, Charlotte Kloft, Robin Michelet, Jan Felix Joseph, Jean-Claude Sirard, Sebastian G. Wicha, Tania Fuhrmann-Selter, Sebastian Franck |
---|---|
Přispěvatelé: | Institut für Pharmazie, Freie Universität Berlin, Freie Universität Berlin, Centre d’Infection et d’Immunité de Lille - INSERM U 1019 - UMR 9017 - UMR 8204 (CIIL), Institut Pasteur de Lille, Réseau International des Instituts Pasteur (RIIP)-Réseau International des Instituts Pasteur (RIIP)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Lille-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille)-Centre National de la Recherche Scientifique (CNRS), Sirard, Jean-Claude, Centre National de la Recherche Scientifique (CNRS)-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille)-Université de Lille-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut Pasteur de Lille, Réseau International des Instituts Pasteur (RIIP)-Réseau International des Instituts Pasteur (RIIP) |
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Electrospray
Formic acid Bioanalytical method validation 02 engineering and technology 01 natural sciences Mouse serum Analytical Chemistry Matrix (chemical analysis) Mice chemistry.chemical_compound Limit of Detection Tandem Mass Spectrometry Liquid chromatography–mass spectrometry medicine Animals Protein precipitation Sample preparation Pharmacokinetics LC-MS/MS Chromatography [SDV.MHEP] Life Sciences [q-bio]/Human health and pathology medicine.diagnostic_test Chemistry 010401 analytical chemistry Selected reaction monitoring Amoxicillin [SDV.SP]Life Sciences [q-bio]/Pharmaceutical sciences 021001 nanoscience & nanotechnology 0104 chemical sciences 3. Good health [SDV.SP] Life Sciences [q-bio]/Pharmaceutical sciences Therapeutic drug monitoring Calibration 0210 nano-technology [SDV.MHEP]Life Sciences [q-bio]/Human health and pathology Chromatography Liquid |
Zdroj: | Talanta Talanta, 2019, 201, pp.253-258. ⟨10.1016/j.talanta.2019.03.098⟩ Talanta, Elsevier, 2019, 201, pp.253-258. ⟨10.1016/j.talanta.2019.03.098⟩ |
ISSN: | 0039-9140 |
DOI: | 10.1016/j.talanta.2019.03.098⟩ |
Popis: | International audience; To assess pharmacokinetics of amoxicillin (AMX) in mice, limitations such as a small sampling volume and low drug concentrations have to be addressed. Similar challenges are faced in a clinical framework, e.g. for therapeutic drug monitoring in neonates or small-scale in vitro investigations. An assay enabling quantification of small sample volumes but still at very low concentrations covering a broad concentration range is thus needed. A simple, rapid and highly sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and successfully validated for quantification of AMX in mouse serum according to European Medicines Agency guidelines. Sample preparation enabled the use of only 10 μL of serum, which is 5-fold less than comparable assays and allows to reduce the number of mice used in pharmacokinetic studies. After protein precipitation with 40 μL chilled methanol and dilution of the supernatant with water, the sample was injected into the LC system on a Poroshell 120 Phenyl Hexyl column (2.1 × 100 mm, 2.7 μm). Chromatographic separation was achieved using a gradient method consisting of acetonitrile and ultra-pure water, both with 0.1% (V/V) formic acid. Positive electrospray ionisation in multiple reaction monitoring mode was used for detection and quantification of AMX. Application to murine study samples demonstrated the reliability of the developed method being accurate and precise with a quantification range from 0.01 to 10 μg/mL. The assay is easily transferable due to a simple sample preparation and confirmed stability of AMX under various applied conditions. |
Databáze: | OpenAIRE |
Externí odkaz: |