CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals
Autor: | Helena Kandarova, Sandra Verstraelen, Els Adriaens, L. Nardelli, Agnieszka Drzewiecka, Nathalie Alépée, Karen Hollanders, Jamin A. Willoughby, Robert Guest, K. Gruszka, A.R. Van Rompay, Virginie Leblanc |
---|---|
Rok vydání: | 2018 |
Předmět: |
0301 basic medicine
medicine.medical_specialty Ocular irritation business.industry Epithelium Corneal In vitro toxicology Reproducibility of Results Eye irritation General Medicine Animal Testing Alternatives Toxicology 03 medical and health sciences 030104 developmental biology 0302 clinical medicine medicine.anatomical_structure 030220 oncology & carcinogenesis Ophthalmology Toxicity Tests Irritants medicine Humans sense organs business Corneal epithelium |
Zdroj: | Toxicology in Vitro. 49:11-20 |
ISSN: | 0887-2333 |
DOI: | 10.1016/j.tiv.2017.06.012 |
Popis: | Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. |
Databáze: | OpenAIRE |
Externí odkaz: |