Three-dimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects
Autor: | Cleo Laskari, Philippe Acar, Natesa G. Pandian, Jonathan Rhodes, Kenneth G. Warner, Gerald R. Marx |
---|---|
Rok vydání: | 1999 |
Předmět: |
Adult
Heart Septal Defects Ventricular Male medicine.medical_specialty Down syndrome Adolescent Heart disease Echocardiography Three-Dimensional Heart Septal Defects Atrial Postoperative Complications Mitral valve Internal medicine Image Processing Computer-Assisted medicine Humans Single-Blind Method Prospective Studies cardiovascular diseases Atrioventricular Septal Defect Child A determinant Observer Variation Mitral regurgitation business.industry Infant Mitral Valve Insufficiency Anatomy medicine.disease Echocardiography Doppler Color Surgery medicine.anatomical_structure Echocardiography Child Preschool Doppler color flow Linear Models cardiovascular system Cardiology Feasibility Studies Mitral Valve Female Down Syndrome Cardiology and Cardiovascular Medicine business Complication Echocardiography Transesophageal |
Zdroj: | The American Journal of Cardiology. 83:745-749 |
ISSN: | 0002-9149 |
DOI: | 10.1016/s0002-9149(98)00982-5 |
Popis: | Mitral regurgitation (MR) is a significant complication after atrioventricular septal defect (AVSD) surgery. The relation of the valve leaflet morphology and the MR mechanism remains a conundrum. Two-dimensional echocardiography depicts leaflet edges, whereas volume-rendered 3-dimensional echocardiography provides direct visualization of the surface areas of the mitral valve leaflets. This study examines the relation of mitral valve anatomy as determined by 3-dimensional echocardiography with MR origins in patients after AVSD repair. Twenty-seven patients with AVSD surgery and Doppler color MR were prospectively enrolled (median age was 5 years and 16 patients had Down syndrome). Doppler color flow imaging of the MR jet and 3-dimensional echocardiography of the mitral valve were performed with a probe in the transthoracic or transesophageal position. Enface 3-dimensional views of the mitral valve from the left atrium were reconstructed. Analysis of the 3-dimensional data was possible in 21 of the 27 patients. Mean area ratios of the 3 mitral leaflets were calculated (superior 40 +/- 7%, inferior 35 +/- 5%, mural 25 +/- 6%). Both intra and interobserver variability on the area measurements were5%. In 12 patients (group 1) the jet appeared to emanate medially from the region of coaptation of the superior and inferior components of the anterior leaflet. In 9 patients (group 2) the jet emanated more laterally from the region toward the mural leaflet. The area ratios of the inferior leaflet were 32 +/- 4% in group 1 and 38 +/- 6% in group 2 (p = 0.02). The area ratios of the mural leaflet were 28 +/- 5% in group 1 and 21 +/- 5% in group 2 (p = 0.007). The superior leaflet area ratio was not different in groups 1 and 2, 40 +/- 9% and 41 +/- 6%, respectively. Three-dimensional echocardiography provides new insight into the anatomic determinants of MR following AVSD surgery. |
Databáze: | OpenAIRE |
Externí odkaz: |