Temporally separating Cherenkov radiation in a scintillator probe exposed to a pulsed X-ray beam
Autor: | Marco Petasecca, Peter E Metcalfe, Levi Madden, Anatoly B. Rosenfeld, Enbang Li, James Archer, Martin G Carolan |
---|---|
Rok vydání: | 2017 |
Předmět: |
Time Factors
Physics::Instrumentation and Detectors Cherenkov detector Astrophysics::High Energy Astrophysical Phenomena Biophysics General Physics and Astronomy Scintillator Radiation Linear particle accelerator 030218 nuclear medicine & medical imaging law.invention Ionizing radiation 03 medical and health sciences 0302 clinical medicine Optics law Fiber Optic Technology Radiology Nuclear Medicine and imaging Cherenkov radiation Physics Scintillation Dosimeter business.industry X-Rays General Medicine 030220 oncology & carcinogenesis Scintillation Counting Optoelectronics Particle Accelerators business Algorithms |
Zdroj: | Physica Medica. 42:185-188 |
ISSN: | 1120-1797 |
DOI: | 10.1016/j.ejmp.2017.09.134 |
Popis: | Cherenkov radiation is generated in optical systems exposed to ionising radiation. In water or plastic devices, if the incident radiation has components with high enough energy (for example, electrons or positrons with energy greater than 175 keV), Cherenkov radiation will be generated. A scintillator dosimeter that collects optical light, guided by optical fibre, will have Cherenkov radiation generated throughout the length of fibre exposed to the radiation field and compromise the signal. We present a novel algorithm to separate Cherenkov radiation signal that requires only a single probe, provided the radiation source is pulsed, such as a linear accelerator in external beam radiation therapy. We use a slow scintillator (BC-444) that, in a constant beam of radiation, reaches peak light output after 1 microsecond, while the Cherenkov signal is detected nearly instantly. This allows our algorithm to separate the scintillator signal from the Cherenkov signal. The relative beam profile and depth dose of a linear accelerator 6 MV X-ray field were reconstructed using the algorithm. The optimisation method improved the fit to the ionisation chamber data and improved the reliability of the measurements. The algorithm was able to remove 74% of the Cherenkov light, at the expense of only 1.5% scintillation light. Further characterisation of the Cherenkov radiation signal has the potential to improve the results and allow this method to be used as a simpler optical fibre dosimeter for quality assurance in external beam therapy. |
Databáze: | OpenAIRE |
Externí odkaz: |