Dose calculation of dynamic trajectory radiotherapy using Monte Carlo
Autor: | D. Frauchiger, Daniel Frei, D. Terribilini, Werner Volken, Peter Manser, Michael K. Fix |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Computer science
Computation Monte Carlo method Biophysics Degrees of freedom (statistics) Imaging phantom Linear particle accelerator 030218 nuclear medicine & medical imaging law.invention 03 medical and health sciences 0302 clinical medicine law Humans Radiology Nuclear Medicine and imaging Radiometry Radiological and Ultrasound Technology Phantoms Imaging Radiotherapy Planning Computer-Assisted Truebeam Reproducibility of Results Collimator Radiotherapy Dosage Trajectory Particle Accelerators Algorithm Monte Carlo Method Algorithms |
DOI: | 10.7892/boris.116291 |
Popis: | Purpose Using volumetric modulated arc therapy (VMAT) delivery technique gantry position, multi-leaf collimator (MLC) as well as dose rate change dynamically during the application. However, additional components can be dynamically altered throughout the dose delivery such as the collimator or the couch. Thus, the degrees of freedom increase allowing almost arbitrary dynamic trajectories for the beam. While the dose delivery of such dynamic trajectories for linear accelerators is technically possible, there is currently no dose calculation and validation tool available. Thus, the aim of this work is to develop a dose calculation and verification tool for dynamic trajectories using Monte Carlo (MC) methods. Methods The dose calculation for dynamic trajectories is implemented in the previously developed Swiss Monte Carlo Plan (SMCP). SMCP interfaces the treatment planning system Eclipse with a MC dose calculation algorithm and is already able to handle dynamic MLC and gantry rotations. Hence, the additional dynamic components, namely the collimator and the couch, are described similarly to the dynamic MLC by defining data pairs of positions of the dynamic component and the corresponding MU-fractions. For validation purposes, measurements are performed with the Delta4 phantom and film measurements using the developer mode on a TrueBeam linear accelerator. These measured dose distributions are then compared with the corresponding calculations using SMCP. First, simple academic cases applying one-dimensional movements are investigated and second, more complex dynamic trajectories with several simultaneously moving components are compared considering academic cases as well as a clinically motivated prostate case. Results The dose calculation for dynamic trajectories is successfully implemented into SMCP. The comparisons between the measured and calculated dose distributions for the simple as well as for the more complex situations show an agreement which is generally within 3% of the maximum dose or 3 mm. The required computation time for the dose calculation remains the same when the additional dynamic moving components are included. Conclusion The results obtained for the dose comparisons for simple and complex situations suggest that the extended SMCP is an accurate dose calculation and efficient verification tool for dynamic trajectory radiotherapy. This work was supported by Varian Medical Systems. |
Databáze: | OpenAIRE |
Externí odkaz: |