Role of lumbar interspinous distraction on the neural elements
Autor: | Alex Alfieri, Roberto Gazzeri, Andreas Schwarz, Christian Scheller, Christian Strauss, Julian Prell, Jens Rachinger |
---|---|
Rok vydání: | 2012 |
Předmět: |
Joint Instability
medicine.medical_specialty Spinal stenosis medicine.medical_treatment Osteogenesis Distraction Kyphosis Spinal Stenosis Lumbar Humans Medicine Spinal canal Orthodontics Facet syndrome business.industry Laminectomy General Medicine medicine.disease Low back pain Spine Spondylolisthesis Biomechanical Phenomena Surgery Treatment Outcome medicine.anatomical_structure Costs and Cost Analysis Spinal Diseases Neurology (clinical) medicine.symptom business Spinal Canal |
Zdroj: | Neurosurgical Review. 35:477-484 |
ISSN: | 1437-2320 0344-5607 |
DOI: | 10.1007/s10143-012-0394-1 |
Popis: | The interspinous distraction devices are used to treat variable pathologies ranging from facet syndrome, diskogenic low back pain, degenerative spinal stenosis, diskopathy, spondylolisthesis, and instability. The insertion of a posterior element with an interspinous device (ISD) is commonly judged responsive to a relative kyphosis of a lumbar segment with a moderate but persistent increase of the spinal canal and of the foraminal width and area, and without influence on low-grade spondylolisthesis. The consequence is the need of shared specific biomechanical concepts to give for each degenerative problem the right indication through a critical analysis of all available experimental and clinical biomechanical data. We reviewed systematically the available clinical and experimental data about kyphosis, enlargement of the spinal canal, distraction of the interspinous distance, increase of the neural foramina, ligamentous structures, load of the posterior annulus, intradiskal pressure, strength of the spinous processes, degeneration of the adjacent segment, complications, and cost-effectiveness of the ISD. The existing literature does not provide actual scientific evidence over the superiority of the ISD strategy, but most of the experimental and clinical data show a challenging potential. These considerations are applicable with different types of ISD with only few differences between the different categories. Despite--or because of--the low invasiveness of the surgical implantation of the ISD, this technique promises to play a major role in the future degenerative lumbar microsurgery. The main indications for ISD remain lumbar spinal stenoses and painful facet arthroses. A clear documented contraindication is the presence of an anterolisthesis. Nevertheless, the existing literature does not provide evidence of superiority of outcome and cost-effectiveness of the ISD strategy over laminectomy or other surgical procedures. At this time, the devices should be used in clinical randomized independent trials in order to obtain more information concerning the most advantageous optimal indication or, in selected cases, to treat tailored indications. |
Databáze: | OpenAIRE |
Externí odkaz: |