Implementation of a real‐time, ultrasound‐guided prostate HDR brachytherapy program
Autor: | Blake R. Smith, Jennifer D. Kos, Joseph M. Caster, Abigail E Besemer, Yusung Kim, Ryan T. Flynn, David Dunkerley, Bonnie S. Wagner, Sarah A. Strand |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Male
Image quality Computer science medicine.medical_treatment Brachytherapy Software Calibration medicine Radiation Oncology Physics Humans Radiology Nuclear Medicine and imaging Stepper Radiation treatment planning Instrumentation Simulation Ultrasonography Interventional Ultrasonography Radiation business.industry Radiotherapy Planning Computer-Assisted Prostate Radiotherapy Dosage Fiducial marker business Quality assurance |
Zdroj: | Journal of Applied Clinical Medical Physics |
ISSN: | 1526-9914 |
Popis: | This work presents a comprehensive commissioning and workflow development process of a real‐time, ultrasound (US) image‐guided treatment planning system (TPS), a stepper and a US unit. To adequately benchmark the system, commissioning tasks were separated into (1) US imaging, (2) stepper mechanical, and (3) treatment planning aspects. Quality assurance US imaging measurements were performed following the AAPM TG‐128 and GEC‐ESTRO recommendations and consisted of benchmarking the spatial resolution, accuracy, and low‐contrast detectability. Mechanical tests were first used to benchmark the electronic encoders within the stepper and were later expanded to evaluate the needle free length calculation accuracy. Needle reconstruction accuracy was rigorously evaluated at the treatment planning level. The calibration length of each probe was redundantly checked between the calculated and measured needle free length, which was found to be within 1 mm for a variety of scenarios. Needle placement relative to a reference fiducial and coincidence of imaging coordinate origins were verified to within 1 mm in both sagittal and transverse imaging planes. The source strength was also calibrated within the interstitial needle and was found to be 1.14% lower than when measured in a plastic needle. Dose calculations in the TPS and secondary dose calculation software were benchmarked against manual TG‐43 calculations. Calculations among the three calculation methods agreed within 1% for all calculated points. Source positioning and dummy coincidence was tested following the recommendations of the TG‐40 report. Finally, the development of the clinical workflow, checklists, and planning objectives are discussed and included within this report. The commissioning of real‐time, US‐guided HDR prostate systems requires careful consideration among several facets including the image quality, dosimetric, and mechanical accuracy. The TPS relies on each of these components to develop and administer a treatment plan, and as such, should be carefully examined. |
Databáze: | OpenAIRE |
Externí odkaz: |