Digital Technologies in the Surgical Treatment of Post-Traumatic Zygomatico-Orbital Deformities
Autor: | R O Gorbatov, E A Durnovo, Yu. V Vysel’tseva, N E Khomutinnikova |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
medicine.medical_treatment Enophthalmos General Biochemistry Genetics and Molecular Biology Orbital Floor Implants medicine Humans Surgical treatment Orbital Fractures three-dimensional modeling of implants Digital Technology Rehabilitation business.industry Clinical Supplements digital technologies in the treatment of facial injuries orbital reconstruction General Medicine Plastic Surgery Procedures Surgical Injury Surgery post-traumatic deformity Zygomatic bone Radiological weapon zygomatico-orbital complex facial implants Implant medicine.symptom business Orbit orbital deformity |
Zdroj: | Modern Technologies in Medicine |
ISSN: | 2076-4243 |
Popis: | The aim of the study was to determine the efficacy of using digital technologies in patients with post-traumatic deformities of the zygomatico-orbital complex (ZOC) by comparing the results with the conventional methods of surgical treatment. Materials and Methods. The article summarizes treatment results of 231 patients with ZOC injuries who underwent surgery at the clinical facilities of Privolzhsky Research Medical University (Nizhny Novgorod) in 2011–2019. There were treated 44.2% (102/231) of patients with post-traumatic deformities of ZOC, including 38.2% (39/102) with post-traumatic defects and deformities of the orbital floor. Based on clinical and radiological planning of surgical operations, the patients were divided into two groups: group 1 included patients who underwent surgery without preoperative virtual planning (54.9% (56/102) of cases), group 2 included patients who underwent virtually planned surgical interventions (45.1% (46/102) of cases). There were 22 and 17 patients with orbital deformities in groups 1 and 2, respectively. Results. The optimal restoration of ZOC anatomy was observed in 75% (42/56) of patients in group 1 and 93.5% (43/46) of patients in group 2. During reconstruction of the orbital floor in patients of group 1, successful results were achieved in 68.2% (15/22) of cases and 88.2% (15/17) in group 2, various complications were observed in the rest of cases. Based on the analysis of surgical treatment results, there was developed a personalized approach to manufacturing of zygomatic bone and orbital floor implants using computer modeling and 3D printing technologies. Conclusion. In contrast to the conventional methods, the use of digital technologies in the surgical treatment of post-traumatic deformities of ZOC allows avoiding the problematic issues of implant positioning and the development of complications during reconstruction, significantly reducing surgical injury and improving patient rehabilitation. |
Databáze: | OpenAIRE |
Externí odkaz: |